Ashly 2.24GS Скачать руководство пользователя страница 1

ASHLY AUDIO INC.

847 Holt Road   Webster, NY   14580-9103  Phone: (716) 872-0010

 Toll-Free: (800) 828-6308  Fax: (716) 872-0739

www.ashly.com

Digital Audio Products

SYSTEM II

Operating Manual

4.24G - Four Channel Graphic Equalizer/System Processor

4.24GS - Four Channel Graphic Equalizer/System Processor Slave

2.24GS - Two Channel Graphic Equalizer/System Processor Slave

4.24PS - Four Channel Parametric Equalizer/System Processor Slave

2.24PS - Two Channel Parametric Equalizer/System Processor Slave

4.24RD - Full Function Graphic Equalizer Remote Control

Protea System Software

Содержание 2.24GS

Страница 1: ...24G Four Channel Graphic Equalizer System Processor 4 24GS Four Channel Graphic Equalizer System Processor Slave 2 24GS Two Channel Graphic Equalizer System Processor Slave 4 24PS Four Channel Paramet...

Страница 2: ...4 24RD Remote Control Unit 6 4 3 Multi Channel Protea System 6 4 4 Computer Control with Protea System Software 7 4 5 With Third Party MIDI System 7 5 KEYBOARD CONTROL FEATURES 7 5 1 Bank 7 5 2 Chann...

Страница 3: ...T BE EARTHED The exclamation point within an eqilateral triangle is intended to alert the user to the presence of important operating and maintenance instructions in the literature accompanying the de...

Страница 4: ...ucts Digital Audio Products PU SH 4 24RD Portable remote control for 4 24G Master or graphic EQ slave units TwoChannel 24 Bit Digital Graphic Equalizer SystemProcessorSlave Digital Audio Products Powe...

Страница 5: ...rotea System Software The second type of interface uses Ashly PROTEA SYSTEM SOFTWARE for the Windows95 98 environment which allows complete PC control through a computer s RS 232 serial port Protea Sy...

Страница 6: ...y includes five audio processors a remote control and Protea System Software Various Protea units can be combined to expand the capabilities of a system adding channels utilizing remote control or con...

Страница 7: ...rent dominant channel Preset 01 EQ IN Cmp Lim OUT HPF LPF OUT DELAY OUT Sig Mute 1 2 3 4 More Menu Channel A B C D Bank Four Channel 24 Bit Digital Graphic Equalizer System Processor A B C D E F G H I...

Страница 8: ...equalizer consists of 28 bands of Constant Q reciprocal filters on third octave frequencies with up down keys for each band Multiple bands can be adjusted at the same time and in dividual frequencies...

Страница 9: ...PF The HIGHPASS and LOWPASS filters of fer precise frequency adjustment of two 24dB oc tave filters creating accurate visual representation of the pass band The frequency indicated for each filter is...

Страница 10: ...ommunication is used to connect the PC to the first Protea unit in that system Master MIDI and RS232 switch menu settings for specific products in various applications can be found in the System Confi...

Страница 11: ...up The user may view but not change the current settings of all local channels user preferences and MIDI Once the proper security level has been selected press the ENTER softkey or Esc to initiate Not...

Страница 12: ...if applicable that you want to copy to then press COPY again to execute the copy or ESC to exit Note The new channel which was copied to becomes the current channel and although the new channel s pres...

Страница 13: ...r on Caution doing this will erase all current presets To do a factory reset on a slave unit set back panel Switch A OUT and Switch B IN then power up unit A 10 second countdown occurs on the LED char...

Страница 14: ...ections and software setups used in Pro tea applications see the SYSTEM CONFIGURATION chart on page 20 6 4 CONTACT CLOSURES and Remote Scene Recall Slaves Only Protea slaves store individual presets a...

Страница 15: ...rotea system channels set to that MIDI channel will respond accordingly Note Simultaneous adjustments made on a 4 24G main unit and 4 24RD remote control will be treated as first come first served in...

Страница 16: ...Slave Parametric slaves will only respond to commands from Protea System Software and while both types of slaves can be used together it is best to only use PC control for such hybrid systems To conf...

Страница 17: ...require Protea System Software to initially set up the presets and scenes The software is flexible enough to set up as little as a two channel slave unit or as much as a full 16 channel stereo graphi...

Страница 18: ...qualified service technician The Protea processors contain an inter nal coin cell battery used to store presets and user preference settings This battery will typically last 5 years or longer The batt...

Страница 19: ...d Signal Present Clip 15dBu 20dBu Audio Sampling Rate 48KHz Propagation Delay 1 46mS Remote Distance 1000 ft AC Requirements 90 125VAC 50 60Hz 180VAC 250VAC 50 60Hz switchable Environmental 40 F 120 F...

Страница 20: ...4 24G RS 232 In RS 232 Slaves XLR In Out PC 1 Slave RS 232 In Out PC Multiple RS 232 to 1st In In on 1st Slave Slaves XLR to others In Out on others PROTEA Rev 2 20 Printed in USA 12 99 PROTEA SYSTEM...