A
IMPORTANT SAFETY INFORMATION ABOUT
PROPANE {LP) GAS
A
A self-contained LP-gas cylinder for use with this appliance must have a capacity of 20
lbs. and must be equipped with a Type 1 connector and an OP D (overfill protection
device). See Figure 1.
The LP-gas sµpp|y cy|inder to be used must be constructed and marked in accordance
with the specification for LP- gas cylinders of the U.S. Department of Transportation
(DOT) or the National Standard of Canada, CAN/CSA-8339, Cylinder, Sphere and
Tubes for the Transportation of Dangerous Goods.
•
The cylinder supply system must be arranged for vapor withdrawal.
•
The cylinder used must include a collar to protect the cylinder valve.
•
This appliance shall be used only outdoors in a well-ventilated space and shall
not be used in a building, garage or any other enclosed space.
•
When this appliance is not is use, the gas must be turned off at the supply
cylinder.
•
Storage of this appliance indoors is permissible only if the cylinder is
disconnected and removed from the appliance.
•
Cylinders must be stored outdoors in a well-ventilated area out of the reach
of children. Disconnected cylinders must have threaded valve plugs tightly installed
and must not be stored in a building, garage or any other enclosed areas.
CSA (Canadian Standards Association) certified to ANSI Z21.97•CSA 2.41-2017
"Outdoor Decorative Gas Appliances".
Figure 1
SPECIFICATIONS
INPUT
Propane Regulator
Pressure
Natural Gas Minimum
Inlet Pressure
Clearances to
50,000 Btu/hr
11 inches water column
7 inches water column
Sides: 30in./ 76.2cm
Top: 58 in. / 147.3 cm
combustible surfaces
Page 7 of17
P187-776