Page 211
T850 Hardware Revisions, Sensor Ports and Sensors
Rev B
No on-board sensor port:
EventSensors (Type1) / CCU32/64 (Type1)
Yes. Connect sensor to Serial Port I/O1 set to ESBUS mode, with an RS232/ES Bus Adapter (part #4162-010).
PB1
No
EventSensor (Type2) / ES-CCU32/64 (Type2)
Yes.
IF
the T850 has a 4SJ expansion card installed, connect to any 4SJ port with an ES-CAB8 cable.
PB2
No, a PB2 is only supported by on-board sensor ports, and will not work if connected to a 4SJ expansion card.
Since the Rev B T850 has no on-board sensor port, the PB2 is not supported.
SensorJack (Type3)
No
EventSensor (Type1) sensors cannot be daisy-chained with EventSensor (Type2) sensors; however, you can use
EventSensor (Type1) sensors connected to Serial Port I/O1
and
EventSensor (Type2) sensors connected to a
4SJ expansion card simultaneously. Just make sure the DIP Switches on all are set so that there are no slotting
conflicts.