![Asentria Teleboss 850 Скачать руководство пользователя страница 156](http://html.mh-extra.com/html/asentria/teleboss-850/teleboss-850_user-manual_2981745156.webp)
TeleBoss 850 2.06.280_STD User Manual
Page 150
Syslog
The Syslog IP Record Collection protocol allows the T850 to receive syslog messages from any Cisco voice-enabled
router, including
Cisco CallManager Express
.
TeleBoss 850 - IP Record Collection (IPRC) Setup
A) IP Record Collection [SYSLOG]
B) Store Collected Data In [FILE1]
C) Data Alarm/Filter Enable [OFF]
D) Target Name [IPRC 1]
E) TCP Port [1468]
F) UDP Port [514]
G) Time Stamping [OFF]
H) Multiline Record Enable [OFF]
I) Division Target 1 []
J) Division Target 2 []
Syslog IP Record Collection protocol is based on the BSD Syslog protocol. Messages are typically a single line of
text, however, they are occasionally longer than one line of text (> 506 bytes) so the T850 features an option to break
the oversize record into multiple lines, and assemble the component single lines into one multiline record. The impact
of this is that the user has to take this into account when defining data alarms. To make it more predictable to the
user where the unit divides an oversize message, there are additional settings called
division targets
(strings up to 8
characters). If the unit needs to divide an oversize message, it tries to make it so that the division target is the
beginning of the remainder piece. The BSD syslog protocol specifies that a message can be 1024 bytes. So the
worst case is that the unit must store a 1024-byte single-line record. The minimum number of divisions necessary to
break a 1024-byte message into records of acceptable size is 2. Therefore there are 2 division target settings. If the
division targets fail to work through misconfiguration then the unit divides the message such that the 1st, 507th, and
1013th bytes are the first bytes of each of the new records.
IP Record Collection
sets the protocol to be used to Syslog.
Store Collected Data In
toggles the FILE to which all incoming Syslog data will be stored. Options are FILE1, FILE2,
AUX1, AUX2, and AUX3. Default setting is FILE1.
Data Alarm/Filter Enable
is an ON/OFF toggle to set whether configured Data Alarms or Filters will be applied to the
incoming data. Default setting is OFF.
Target Name
is the name used to identify the switch when an IPRC Connection Lost Alarm is sent via an
AsentriaAlarm. Default setting is IPRC 1.
TCP Port
sets the TCP port used by the sending Cisco device. Default setting is port 1468.
UDP Port
sets the UDP port used by the sending Cisco device. Default setting is port 514.
Time Stamping
is an ON/OFF toggle to set whether each individual call record is stamped with the Date and Time
received in the T850. Default setting is OFF.
displays the Multiline Record Settings menu.
Division Target 1 / 2
are eight charaters text strings used to designate the beginning of a section of a divided
oversize record. Default settings are blank.
Multiline Record Settings
TeleBoss 850 - IPRC Multiline Record Settings
A) Multiline Record Enable [OFF]
B) Blank Line Count [0]
C) Complex Multiline Detection [OFF]