Event Log Settings
The Event Log is a record of all data events that occur within the TeleBoss.
The Event Log overwrites itself when it becomes full. “Full” has meaning that you can control with the
Maximum File Size setting. This setting controls the maximum size (in KB) to which the file should be limited.
If the setting is 0 then the audit lo
g’s only constraint on size will be the available physical memory.
TeleBoss 830 - Event Log Settings
A) List Events File
B) Clear Events File
C) Enable Events Log File [ON]
D) Maximum File Size [32]
E) Store Data Alarm Records [OFF]
F) Store Sensor Events [OFF]
G) Date/Time Stamp Data Alarm Records [OFF]
H) Prepend Data Alarm Name [OFF]
List Events File
Choosing this option will display the contents of the Events File, if any records exist.
Clear Events File
Entering the letter for this selection will purge the records within the Events File.
Caution:
The records in the Events File are deleted immediately when this option is selected.
Enable Events Log File
This is an ON/OFF toggle to enable Event logging. The default setting is ON.
Maximum File Size
This field will set the maximum number of KB the event log can reach before overwriting the oldest records.
The available options are 0, 64, 128, 256, 512, and 1024. The default setting is 32.
Store Data Alarm Records
This option is an ON/OFF toggle to enable storing data alarm records. The default setting is OFF.
Store Sensor Events
This is an ON/OFF toggle to enable storing records generated by environmental sensors. The default setting
is OFF.
Date/Time Stamp Data Alarm Records
This is an ON/OFF toggle to prepend a Date/Time stamp to the beginning of data alarm records. The default
setting is OFF.
Prepend Data Alarm Name
This is an ON/OFF toggle to prepend the name of the Data Alarm to the beginning of the data alarm record.
This aids in identifying which Data Alarm an alarm record is associated with. The default setting is OFF.