TeleBoss 830 2.11.370 STD User Manual
Page 112
Schedule n Duration
These fields set the number of minutes (0-65535) the unit will wait without receiving data before alarming.
Apply Alarm on Days
This option displays a menu where the seven days of the week are listed, and each can be toggled ON or
OFF to designate whether this particular No-Data alarm is active on that day. The default setting is ON for
Monday thru Friday, and OFF for Saturday and Sunday.
Enable Ports
This selection displays a menu where the installed serial ports are listed and each can be toggled ON or OFF
to designate whether this particular No-Data alarm is active on that port. The default setting is OFF for all
ports.
Add Exclusion / Delete Exclusion
These fields allow you to add or delete specific dates when this No-
Data Alarm should “take the day off”. For
example Christmas is a day you might want to add here. Select Add Exclusion and type in 12/25. To delete a
date, select Delete Exclusion and type in the date you want to remove. After an exclusion date is added it
appears in the brackets at the bottom of the menu. Up to fifteen dates can be entered to be excluded.
No-Data Alarm Settings as accessed via Web UI
The No-Data Alarms Settings are located in the Events menu on the left hand menu. Use the drop down in
the header to toggle to the second No-Data Alarm Settings page.
Percent Full Alarm Settings
Percent Full Alarms send an alarm when the Teleboss buffer reaches a certain Percentage of full memory.
This feature can send an alarm message before the unit fills to capacity.
TeleBoss 830 - Percent Full Alarm Settings
A) Alarm Enable [OFF]
B) Percent Full Threshold [80]
C) Alarm Actions []
D) Alarm Message [DB Exceeds Threshold]
E) Alarm Class [Info]
F) Trap Number [501]