background image

CZ

10

Initial start

PP10 is switched on by connecting to the power supply. PP10power supply 
must be connected together with the power supply of the circulation pump. 
Switching off  the circulation pump must switch off  the PP10, otherwise incor-
rect dosing would occur. 

It is advisable to test the connecting pipe tightness before normal usage. 
After starting the device, dosing starts. Visually check the dosing liquid for 
leaks at any joint. After switching off  the device, check that the liquid in the 
hose does not fall back.

Initial setup

PP10 PRG

1. 

When the mains cable is plugged in, the LED display of the device lights 
up.

2. 

Press any + or - button to switch the device to setting mode. In setting 
mode, the display starts fl ashing.

3. 

Use the + and - buttons on the display to set the hour dose. One press 
changes the value by one unit, holding the button changes the displayed 
value faster.

4. 

After completing the setting, the display fl ashes for approx. 10 seconds 
and then the pump automatically starts the set dosing.

PP10 12V

After connecting the pump, it continuously doses 10 ml / m.

Содержание PP10

Страница 1: ...USER MANUAL PP10 EN PROGRAMMABLE PERISTALTIC PUMP FOR SLOW CONTINUOUS DOSING www asekopool com ...

Страница 2: ...rdosing of chemical agents Potential consequence Injury heavy material damage Design your installation such that uncontrolled dosage is not possible in the event of a probe failure or other errors and or such that uncontrolled dosage is recognized and halted before damage is incurred Uncontrolled overdose of chemicals can cause harm to health and property Even though the device contains a number o...

Страница 3: ... pH value is wrong If disinfection is enabled before the pH value is stable in the ideal range of 7 0 to 7 4 then it may lead to heavy overdosing of chlorine or bromine Potential consequence Injury heavy material damage Do not start disinfection with chlorine until the pH value is stable in the ideal range between 7 0 and 7 4 Conditions before using Make sure you have a newest and updated version ...

Страница 4: ... 4 What s in the box Peristaltic pump 12117 Peristaltic pump 12117 Injection valve 2 pcs 12005 Suction tube weight 2 pcs 12023 Dowels and screws PE Tube 1 4 6 35 mm transparent 12008 PP10 13260 PP10 13260 ...

Страница 5: ...EN 5 Optional accessories ASEKO original chemicals Inserting DN50 plug 1 4 threaded 12134 Coagulation mixer 30001 30001 FLOC C 20l 12139 FLOC C 5l 12138 ...

Страница 6: ...ts The PP10 PRG variant is equipped with a power supply cable and allows you to set the hour dose on the built in display The PP10 12V variant has no display and continuously doses 10 ml m PP10 12V is designed for connection to the ASIN Aqua Profi control system Technical description Power supply 230 V 50 Hz Power consumption 4 5 VA Fuse T500 mA Over voltage category II Ingress protection IP50 Ope...

Страница 7: ...re provided WARNING The location temperature should permanently be in the range from 5 C to 40 C Direct sunlight high humidity and dust may lead to damage to PP10 Before installing ensure that pool water is chemically clean and free of dirt The maximum distance of injection valves from peristaltic pump of PP10 must not be greater than 8 m Vertical distance between PP10 and the bottom of containers...

Страница 8: ...e cap Select the tube distance so that the tube reaches the canister bottom and can be connected to the pump as straight as possible A long tube in the canister would bend and produce air bubbles 3 Put a weight on the tube end and dive it in the canister 4 Connect the plastic tube from the canister to the left connection of the peristaltic pump 5 Connect the plastic tube to the right connection of...

Страница 9: ...EN 9 Max 8 m Max 8 m Max 2 m TO POOL Heating FROM POOL Besgo Coagulation mixer Sampling point ...

Страница 10: ...nt After switching off the device check that the liquid in the hose does not fall back Initial setup PP10 PRG 1 When the mains cable is plugged in the LED display of the device lights up 2 Press any or button to switch the device to setting mode In setting mode the display starts flashing 3 Use the and buttons on the display to set the hour dose One press changes the value by one unit holding the ...

Страница 11: ...r being clogged with impurities or deposits or the rubber seal for being damaged Failure of dosing pump Check whether pump is running If so check the hose inside the pump for damage or breakage and replace it if required Fuse failed If the input voltage to the peristaltic pump is OK and the pump does not work the mains fuse may have failed The fuse is located on the PCB inside of the device To rep...

Страница 12: ...e the new hose with the supplied special grease Insert the lubricated hose into the cassette Place the cover cassette back on PP10 and turn it clockwise to lock it Use new nuts which are part of the replacement hose set for connection of the PE tube Injection Valve Maintenance On a regular basis check throughput of the injection valves rubber band integrity remove scale In case of private pools re...

Страница 13: ...cles that can be removed by filtering Coagulation inorganic coagulant 1 second Flocculation polymeric flocculant approx 3 minutes Filtration AFM Activated Filter Media Filter Media ZPM Zeta Potential Mixer Polymeric flocculant causes that neutral particles join together to create solid floccules Solid floccules are easily caught by filter media A zeta charge of suspended particles is neutralised i...

Страница 14: ...EN 14 ...

Страница 15: ...CZ 15 ...

Страница 16: ...www asekopool com PP10 USER S MANUAL EN ...

Отзывы: