Use of new functions

Because of the continued development, a ASIN Aqua® unit may contain functions, which are not 
completely described in this version of the user manual. The use of such new or extended functions 
without a profound and secure understanding by the operator may result in malfunctions and severe 
problems. Potential consequence: Injury, heavy material damage.

•   Make sure to get a profound and secure understanding of a function 

and relevant boundary conditions, before you start to use it.

•  Check for an updated version of the user manual or additional 

documentation available for the relevant functions.

•  Make use of the integrated help function of the ASIN Aqua® to get 

detailed information on   functions and their parameter settings.

•  In case it should not be possible to get a profound and secure understanding of a 

function based  on the available documentation, do not use this function.

Overdosing if pH value is wrong

If disinfection is enabled before the pH value is stable in the ideal range of 7.0 to 7.4, then it may lead 
to heavy overdosing of chlorine or bromine. Potential consequence: Injury, heavy material damage.

•  Do not start disinfection with chlorine until the pH value is 

stable in the ideal range between 7.0 and 7.4.

Conditions before using

Make sure you have a newest and updated version of the user manual and other documentation for 
all functions of the unit. Use and read the integrated help features. In case of not understanding the 
information about certain features of the unit, do not use these features.

Handling chemicals for pool water treatment

The chemicals used with the ASIN Aqua must be handled in a safe manner to prevent damage or personal 
harm. Aseko recommends you always use personal protective safety equipment when handling the pH 
and chlorine agents. Refer to the Materials Safety Data Sheet (MSDS).

WARNING:

Never mix the pH agent with the chlorine agent. When carrying out maintenance on 

the clear plastic tubes or valves always rinse with clean water to prevent mixing of the pH and chlorine 
agents.

Содержание ASIN AQUA Oxygen VS

Страница 1: ...ASIN AQUA Oxygen VS POWER OF SYNERGIE 2021 EN www asekopool com USER MANUAL INTEGRATED VS PUMP CONTROL for crystal clear pool water without chlorine ...

Страница 2: ...rdosing of chemical agents Potential consequence Injury heavy material damage Design your installation such that uncontrolled dosage is not possible in the event of a probe failure or other errors and or such that uncontrolled dosage is recognized and halted before damage is incurred Uncontrolled overdose of chemicals can cause harm to health and property Even though the device contains a number o...

Страница 3: ... pH value is wrong If disinfection is enabled before the pH value is stable in the ideal range of 7 0 to 7 4 then it may lead to heavy overdosing of chlorine or bromine Potential consequence Injury heavy material damage Do not start disinfection with chlorine until the pH value is stable in the ideal range between 7 0 and 7 4 Conditions before using Make sure you have a newest and updated version ...

Страница 4: ...g 2 pcs 12013 Electronic flowmeter with filter 12106 Peristaltic pumps Peristaltic pumps 12093 12093 Water thermometer with housing 13192 Long Life pH Probe 12012 Long Life pH Probe 12012 Wrench socket for probes 13046 NEW Coagulation mixer Coagulation mixer PE Tube 1 4 6 35 mm transparent 15m 12008 Water valves 2 pcs 12006 Injection valve 4 pcs 12005 Suction tube weight 4 pcs 12023 ...

Страница 5: ...086 Air thermometer 13192 Inserting DN50 plug 1 4 threaded 12134 pH 7 00 Buffer 12065 Optional accessories ASEKO original chemical solution OXY PURE 13039 ALGICID 12157 pH MINUS 12131 pH MINUS 12131 FLOC C 12138 SUPER CHLOR 13120 OXY PURE 13038 ALGICID 12156 pH MINUS 12130 pH PLUS 12120 FLOC C 12139 ...

Страница 6: ...tion and removal of algae is the modern polymeric ALGICIDE being non oxidative hence very comfortable for skin The OXYPURE preparation then only serves for oxidation of water and its sparkly appearance Pool water treatment Well balanced combination of all treatment aids will provide cleanand crystal clear water OXY Pure Active oxygen for clean and crystal clear water pH control ASIN AQUA Oxygen ma...

Страница 7: ...an optional Besgo valve for automatic backwashing Smart Heating Control The system is equipped by intelligent control of preset water temperature It can switch and control the heating electrical heating gas heating heat exchanger by logic of integrated smart heating functions The system must be equipped by optional air thermometer Freeze Protection Unless you want to drain the pool for the winter ...

Страница 8: ...50 cm are provided Drill three holes in the wall at the distance of 18 5 cm Use screws supplied with ASIN AQUA Oxygen for attachment WARNING The location temperature should permanently be in the range from 5 C to 40 C Direct sunlight high humidity and dust may lead to damage to ASIN AQUA Oxygen Before installing ensure that pool water is chemically clean and free of dirt The maximum distance of in...

Страница 9: ...r ring After the probe have been inserted slightly tightened and connectors have been connected ASIN AQUA Oxygen is ready for connection to the water system of your pool WARNING Only hand tighten the probe or use the attached plastic wrench socket for probes Do not use pliers or steel wrench pH Long Life probe pH Long Life probe 12012 pH probe housing 12013 Wrench socket for probes 13046 probes 13...

Страница 10: ...t and pull the interconnecting tube out WARNING To treat PE tube ends use a sharp knife part of delivery The use of scissors or tongs deforms the tube end and leads to leaks WARNING Only hand tighten Do not use tongs or any other tools 1 To ensure tightness of joints cut the tube at 90 angle Use the sharp knife to cut plastic The cut must be clean and smooth 2 Connect the water inlet to the measur...

Страница 11: ...UTLET CAN BE REALISED 1 downstream of filtration 2 to non pressure overflow tank TO POOL Heating FROM POOL POOL WATER INLET WATER INLET IN IN OUT Besgo Coagulation mixer Water thermometer Max pool water pressure 1 5 Bar ...

Страница 12: ...possible A long tube in the canister would bend and produce air bubbles 3 Put a weight on the tube end and dive it in the canister 4 Connect the plastic tube from the OXYPUREcanister to the ASIN AQUA Oxygen pump marked as 1 CHLORINE to the left connection 5 Connect the plastic tube to the 1 CHLORINE pump right connection and the injection valve 6 Hand screw the OXYPUREinjection valve in the specif...

Страница 13: ...EN 13 Max 8 m Max 8 m Max 2 m TO POOL Heating FROM POOL Coagulation mixer ...

Страница 14: ...3 36 37 38 39 40 Flow T water T out Level Cover Timer Bottom B wash Filling Heating VS pump RS 485 Display 230 V 50 Hz T800mA N L N L POWER SUPPLY 230 V 50 Hz Roller shutter position POTENTIAL FREE RELAY Without Without function Heating relay Solenoid valve filling Besgo valve 5W Filterbackwash Besgo valve 3W OFF Bottom ON Overflow Water level Water level sensor Air Air thermometer Water Water the...

Страница 15: ... Speed 0 Speed 1 Speed 2 Speed 3 STOP LOW MEDIUM HIGH 24 25 22 21 23 C DI1 DI2 DI3 DI4 HAYWARD older type TYP C COM 0 1 2 3 VS pump COM Speed 0 Speed 1 Speed 2 Speed 3 STOP LOW MEDIUM HIGH 24 25 22 21 23 GND SPEED 1 SPEED 2 SPEED 3 NOT CONNECTED UWE EO PM TYP A COM 0 1 2 3 VS pump COM Speed 0 Speed 1 Speed 2 Speed 3 STOP LOW MEDIUM HIGH 24 22 23 21 3 6 7 8 11 DAB E SWIM E PRO TYP B COM 0 1 2 3 VS ...

Страница 16: ...z socket outlet 3 Disconnect the filtering unit mains cable from ASIN AQUA Oxygen WARNING If Device is used in the manner different from that specified by the manufacturer protection provided by Device may get damaged Power supply 230 V 50 Hz Power consumption 24 VA Power consumption including filter pump 1449 VA Max input power of connected pump 1 4 kW 230 V AC Fuse T800 mA T160 mA T6 3 A Over vo...

Страница 17: ...hey are running check tightness of all the PE tube connections Check the injecting valves for blockage and air bubbles in the PE tube DO NOT FORGET Provide the testing run and stop of all accessories connected to ASIN AQUA Oxygen At this step just test do not dose the aids or provide the initial dose of chemicals Initial dose In following steps 1 2 3 Check tightness of all the connections Liquid m...

Страница 18: ...value in pool water ON filtering follows adjusted period NONSTOP 24 h filtering in operation for 24 hours uninterruptedly Enter settings ON indicates the current status of filtration The timer allows to set the control mode and adjust filtering periods Manual control allows to switch filtration on off independently to preset filtering periods start filter washing independently to adjusted washing ...

Страница 19: ...ge Indicator of the current page and the total number of pages Movement in menu to the next page ON function is switched on OFF function is switched off Back to the main screen Displays help manual for the particular screen Back to the previous screen Reduces the value Increases the value ...

Страница 20: ...des the preset filtering when the standard pump is off it runs at speed 1 or can stay switched off according to your choice In case of backwashing the pump is running at speed 3 Individual speeds 1 2 3 are adjusted directly on the pump according to the respective pump manual Automatic Filter Washing Considering that the ASIN AQUA Oxygen technology is in particular based on the high efficiency of f...

Страница 21: ...r temperature is higher eventually to eliminate the time when noise from heat pump disturbs you neighbor Heating at Outdoor Temperature above or below This function allows to adjust outdoor air temperature at which or below which ASIN AQUA Oxygen starts heating This function requires installation of the outdoor air thermometer 8953 This function is useful to control effectiveness of air heat pumps...

Страница 22: ...er if the water level stay permanently at least for 10 seconds below this value in order to prevent oscillating Low level ALARM Circulation filtering pump shuts off Flowmeter The flowmeter detects flow of measured water Dosing of chemicals will take action only if flow of measured water to probes is detected Wash the check flowmeter strainer on a regular basis Warning Only switch off the flowmeter...

Страница 23: ...htly lower Required pH value refilled water pH value pH may change during operation but if it is in the range from 6 4 to 7 6 you do not have to change this setting ALGICIDE Setting A sufficiently effective dose for most pools is 10 ml m3 per day If green algae appear in the pool you can increase the dose After algae have disappeared the dose can be returned to 10 ml FLOC C Setting A FLOC C dose f...

Страница 24: ...nic active chlorine without stabilizers Follow the instructions on the packaging 1 kg 80 m3 24 Wait at least 1 hour Optimally up to 24 hours If the concentration is lower repeat superchlorination If the concentration is higher wait till the chlorine concentration in the water drop down 4 Open the water supply to the probes the No water supply to the probes notification will disappear from the ASIN...

Страница 25: ...alue does not change even after preset quantity of doses according to the settings ASIN AQUA Oxygen stops pH dosing and an error message appears on the display The other ASIN AQUA Oxygen functions are not limited Maximum Refilling Time The refilling of the pool is limited for the adjusted time ...

Страница 26: ...lue directly in the pool water by means of a photometer Then enter this value into ASIN AQUA Oxygen on the pH Probe Calibration screen Adjustment of OXYPURE Active Oxygen Dose The optimum OXYPURE concentration value is from 50 to 100 mg From time to time check this value by means of the OX tester and adjust the dose in the menu if required Water Thermometer Calibration Ifwatertemperatureisdifferen...

Страница 27: ...ter pH is 7 2 and probe is measuring 7 9 the tolerance is 0 7 so lower than 1 0 the probe is OK Probe response to positive or negative changes in water or buffer example if you dive the probe with dry and clean tip to 7 0 pH buffer the 1 minute response must be at least 90 If the probe meet all above qualifications and the ASIN AQUA Oxygen does not allow calibration it is necessary to upgrade the ...

Страница 28: ...you can use the data transmission over the mobile network Connect the ASIN AQUA Oxygen to your mobile net work router via LAN cable Wifi connection If you install the ASIN AQUA Oxygen in place where is no access to your private network by wired connection but your Wifi has enough signal you can connect the ASIN AQUA Oxygen to your Wifi by use of Wifi extender Powerline via 230V DC If you have no w...

Страница 29: ...EN 29 WIFI EXTENDER 230 V LAN INTERNET Home network 3G LTE Wifi extender Powerline via 230 V socket outlet INTERNET INTERNET INTERNET Connect LAN cable ...

Страница 30: ...le After you connect the ASIN AQUA Oxygen to the internet download the iPool Live application to your smartphone Application is available for iOS and Android operation systems Main screen after opening will ask for typing your ASIN AQUA Oxygen serial number If you have more pools equipped by the ASEKO NET adapter you can load all of them to one application Pool LIVE for iOS Pool LIVE for Android ...

Страница 31: ...ll events taken actions and act levels of monitored items up to 30 days back Transparent graphic environment of chart lines is giving fast report and you can easily see interconnection of monitored values This application is useful at public pool installations where you need to observe the history and monitor the pool water quality and maintenance In case of any discrepancy in water quality you ca...

Страница 32: ...se into the cassette Place the cover cassette back on ASIN AQUA Oxygen and turn it clockwise to lock it Use new nuts which are part of the replacement hose set for connection of the PE tube Injection Valve Maintenance On a regular basis check throughput of the injection valves rubber band integrity remove scale In case of private pools replace injection valve rubber bands every 2 years In case of ...

Страница 33: ...ed water inlet to probes and furthermore from the water outlet from probes to the closing valve Check condition of the extraction valve and the closing valve and their seals for being clogged and their closed position Probe out of Service Measure pH using the hand tester If the pH value is too low a respective agent was overdosed due to an incorrect probe function provided that other reasons given...

Страница 34: ...isplay RS 485 Topení Bez funkce COM Speed 0 Speed 1 Speed 2 Speed 3 STOP LOW MEDIUM HIGH Bezpotencionální relé Řízení variabilního čerpadla Inputs Sepnuto zavřená Rozepnuto otevřená Salinita 24 25 22 21 1 2 23 8 7 3 4 5 6 9 10 19 20 Besgo 3 W Dnová výpust 30 31 26 27 28 29 13 12 11 14 13 14 11 12 Externes Touchscreen Display The external display shows 1 Pool water parameters Temperature pH value r...

Страница 35: ...cles that can be removed by filtering Coagulation inorganic coagulant 1 second Flocculation polymeric flocculant approx 3 minutes Filtration AFM Activated Filter Media Filter Media ZPM Zeta Potential Mixer Polymeric flocculant causes that neutral particles join together to create solid floccules Solid floccules are easily caught by filter media A zeta charge of suspended particles is neutralised i...

Страница 36: ...www asekopool com ASIN AQUA Oxygen VS USER MANUAL EN ...