6. 5. 4
Basic system self-test
Self-tests are run automatically after a restart caused by an interruption in the
power supply or after a PBX reset. The scope of the tests can be influenced during
the startup process using the HEX rotary switch on the mainboard.
Tab. 109 HEX rotary switch
Permanently displayed
Action successfully completed
Timeout symbol (permanently lit)
Timeout for turning HEX rotary switch
Flashing
Waiting for V.24 transfer
Permanently displayed
Boot mode for EUL via LAN (possible
only as of I7.5)
Segments moving from bottom to top
Loading application via V.24
Rotating segments, forming the letter "o" Data transfer to or from a Flash card
Letter "E" followed by a three-digit figure
and a bar (repeated)
An error with error code nnn has
occurred
2)
Flashing quickly
Generating a "Bad Block Table" after
an unformatted Flash card is inserted.
Warning: Do not interrupt the process
(can take up to 40 s)
1)
A thorough RAM test is carried out when the HEX switch is on position 2. In this case the segments move up
and down slowly.
2)
An overview of error codes can be found in
"Output of error codes in the PBX and on the Crystal", page 248
HEX rotary switch
Position
Remarks
16 positions
Different coding options
7-segment display
Detailed Description
State / Remarks
n n n