Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 3

To exit the programming mode, press no keys for about 30 s 
or keep the 

 key pressed for 2 s.

Previous

Param.

Normal 

mode

Parameter select

(Program mode)

Parameters set

Next

Param.

2 s

5 s

Increase

value

Decrease

value

-25.5

sLs

-30.0

2.3 

Parameter protection using the password

The instrument has a parameter protection function using a 
password that can be personalised through the 

tPP

 parameter

To protect the parameters, set the desired password number 
in the parameter 

tPP

.

When the protection is active, press the 

 key to access 

the parameters and keep it pressed for about 5 s, after which 
the display shows 

r.p

.

Press the 

 key, the display shows 

0

, using the 

/

 keys, 

insert the programmed password number and press the key 

 

again.

If the password is correct the instrument displays the code of 
the first parameter and it will be possible to program the in-
strument in the same way described in the previous section.
The password protection can be disabled by setting 

tPP

 = 

oF

.

2 s

5 s

Increase

value

Decrease

value

-25.5

 rp

   0

 sls

Normal

mode

Password

request

Parameter

(Program mode)

Password

correct

Insert password

Note: 

If the Password gets lost, just switch OFF and ON the 
instrument, push 

 key during the initial test keeping 

it pressed for 5 s.  In this way it is possible to access all 
the parameters, verify and modify the parameter 

tPP

.

2.4 

Customized mode parameter programming 

(parameters programming level)

The password hides all the configuration parameters behind a 
factory set password to avoid unwanted changes to the con-
troller parameters.  To make a parameter accessible without 
having to enter the password when 

tPP

 password protection 

is activate, use the procedure that follows:
Enter the program mode using the 

tPP

 Password and select the 

parameter that must be accessible (no password protection).
Once a parameter is selected, if the 

dp LED flashes

 the 

parameter is programmable by entering the password (is 

protected

”).  If the 

dp LED is steady ON

 the parameter is 

programmable without password (is “

unprotected

”).

To change the parameter visibility, press the 

 key and 

keeping it pressed also press the 

 button.

The 

dp LED

 changes its state indicating the new level of 

parameter accessibility (

ON

 = not protected;  

flashing

 = password protected).

In case some parameters are not protected, accessing 
the the programming mode the display first shows the not 
protected parameters, then the 

r.p

 parameter (through which 

will be possible to access the “protected” parameters).

Normal 

mode

2 s

5 s

Increase

value

Decrease

value

-25.5

 r.p

Previous

Param.

Not protected

parameter

Parameters set

Password

request

Insert password

Password OK

Next

Param.

Increase

value

Decrease

value

AHA

 35.0

   0

 sls

Program Mode

2.5 

Reset parameters to default value

The instrument allows the reset of the parameters to values 
programmed in factory as default
To restore the default parameters value set value 

-48

 at 

r.p

 

password request  Therefore, to make the reset to the default 
parameters, enable the Password using the 

tPP

 parameter 

so that the 

r.p

 setting is requested, at this point insert 

-48

 

instead of the programmed access password.
Once confirmed the password with the 

 key the display 

shows “

---

” for 2 s therefore the instrument resets all the 

parameters to factory default setting.

2.6 

Keyboard lock function

On the instrument it is possible to completely lock the keyboard.
This function is useful when the controller is in an accessible 
area and the changes must be avoided.
To activate the keyboard lock it is enough program the pa-
rameter 

tLo

 to a value different from 

oF

.

The 

tLo

 value is the keys inactivity time after which the key-

board will be automatically locked.
Therefore, pressing no buttons for the time set at 

tLo

, the in-

strument automatically disable the normal functions of the keys.
When the keyboard is locked, if any of the key is pressed, 
the display showss 

Ln

 to indicate that the lock is active.

To unlock the keyboard it is enough to contemporarily push 

 + 

 keys and keep them pushed for 5 s, after which the 

label 

LF

 appears on the display and all the key functions will 

be available again.

Содержание e33

Страница 1: ...rvals by temperature reaching or by con tinuous compressor operation time through stopping the compressor electric heating or hot gas cycle inversion The instrument has up to 3 relay outputs and up to...

Страница 2: ...al mode to program the setpoint is done by mo mentarily pressing the key the display shows SP or SPE alternated to the programmed value To change it press the key to increase the value or to decrease...

Страница 3: ...protected If the dp LED is steady ON the parameter is programmable without password is unprotected To change the parameter visibility press the key and keeping it pressed also press the button The dp...

Страница 4: ...d also after the instrument installation if necessary using proper filters 4 INSTALLATION WARNINGS 4 1 Mechanical mounting The instrument in case 78 x 35 mm is designed for flush in panel mounting Mak...

Страница 5: ...ut 1 R 10 4 A 10 A Res 8 3 A Out 2 8 4 A 2 A Gen Use 5 1 A Out 3 2 1 A 60730 EN UL 5 FUNCTIONS 5 1 ON Stand by function Once powered the instrument can assume 2 different conditions ON Means that the...

Страница 6: ...ith parameter iuP it is possible to select the tempera ture engineering unit and the desired measure resolution C0 C 1 C1 C 0 1 F0 F 1 F1 F 0 1 The instrument allows the measure calibration which can...

Страница 7: ...control the evaporator fans Au To control the auxiliary device At To control a silenceable alarm device through a contact that is NO in normal operation then closed when the alarm sounds AL To control...

Страница 8: ...output In the event of a probe error it is possible to set the instru ment so that that the output continues to work in cycles according to the times programmed with parameter rt1 activation time and...

Страница 9: ...the first defrost after power ON can be set with parameter dSd This allows to perform the first defrost to a different interval from ddi time To force the instrument to perform a defrost cycle at eac...

Страница 10: ...y the EP probe is higher than the one set at param eters dtS and also dtE the defrosting is inhibited dtE dts Defrost dF off off off ON ON A B Temp time C NO defrost dde ddi dSd Defrost ddi dSd ddi dS...

Страница 11: ...change Remember that the fans functioning can be conditioned by the Door open function by the digital input 5 10 Alarm functions The alarm conditions of the instrument are Probe errors E1 E1 E2 E2 and...

Страница 12: ...ON Hi Lo Pr1 or they assume the values SP AHA and SP ALA if the alarms are relative AAy 2 4 6 8 AHA SP ALA off off off ON ON Hi Lo AL AAd AAd Temp time Pr1 The maximum and minimum temperature alarms c...

Страница 13: ...ment are being supplied directly or through the key AC supply Supply adapter 12 VDC Power supply Enter PWS 12 V A B C TTL USB to PC USB Enter PWS 12 V A B C TTL USB to PC USB For additional info pleas...

Страница 14: ...r 2 Open Door with Fan Lock 3 Open Door with Fan and Output Lock 4 External Alarm 5 External alarm with control output disabling 6 Normal Eco select 7 On Stand by select 8 Start a Turbo cycle 9 Defros...

Страница 15: ...1 59 s 1 99 min 10 41 Ftn Fan time activation with ot output compressor OFF oF Function disabled 1 59 s 1 99 min 5 42 FtF Fan time deactivation with ot output compressor OFF oF Function disabled 1 59...

Страница 16: ...bled 1 Active for alarms only 2 Active for key pressed only 3 Active for alarms and key pressed oF 65 oFo Auxiliary output function oF Function disabled 1 Control output ot delayed 2 Manual activation...

Страница 17: ...ults found without any fees or charge for Ascon Tecnologic except in the event of alternative agreements 10 TECHNICAL DATA 10 1 Electrical characteristics Power supply 230 VAC 115 VAC 12 VAC VDC 10 AC...

Страница 18: ...e NTC 103AT11 11 INSTRUMENT ORDERING CODE a POWER SUPPLY D 230 VAC C 115 VAC F 12 VAC VDC b OUTPUT 1 OUT 1 H Out1 Relay SPST NO 16A AC1 for resistive loads R Out1 Relay SPST NO 30A AC1 for resistive l...

Страница 19: ...Ascon Tecnologic e33 OPERATING INSTRUCTIONS PAG 19...

Страница 20: ...Ascon Tecnologic e33 OPERATING INSTRUCTIONS PAG 20...

Отзывы: