background image

TD 92356GB

2007-03-16/ Ver. C

Installation Guide

PCR Charging Rack

Содержание PCR Charging Rack

Страница 1: ...TD 92356GB 2007 03 16 Ver C Installation Guide PCR Charging Rack ...

Страница 2: ... Dimensions 7 3 6 Removing Covers 8 3 6 1 Power Supply Module 8 3 6 2 Charging Rack Module 9 3 6 3 Mounting Modules Together 10 4 Connection of Power Supply CR24 12 4 1 Connection of Mains Power Supply Cable AC 12 4 2 Wiring Run 15 4 3 Connection of Supply Voltage Connector 17 5 Maintenance Information 18 5 1 Upgrading the Software 18 6 Connection of Charging Rack Master PCR M and Extension PCR E ...

Страница 3: ...arging Rack Extension PCR E module and the Power Supply CR24 module Each Charging Rack both Master PCR M and Extension PCR E charges six portables IMPORTANT Power Supply CR24 is the only power supply that can be used together with the PCR Charging Rack PCR Charging Rack Power Supply CR24 Supply voltage 5 V 5V 12A max Current consumption normal operation 100 mA Master PCR M 35 mA Extension PCR E Ma...

Страница 4: ...PLUGGABLE EQUIPMENT the socket outlet shall be installed near the equipment and shall be easily accessible The disconnect device shall disconnect both poles simultaneously For continued protection against risk of fire only replace the fuse in the Charging Rack with the same type and rating of fuse 4A ATAB Art No 210265 Every installation must at least consist of one Power Supply CR24 and one Charg...

Страница 5: ...ws Rectangular assembly covers Clips only used for Power Supply module A modular cable is included in the delivery of Extension PCR E for connection to or from another Extension PCR E or Master PCR M Required tools and material Three wired cable for the mains power with diameter 4 8 5 mm Make sure that the used cable is grounded and approved for the current and voltage in question Screwdrivers Cut...

Страница 6: ...emperature is higher than 25 degrees C the Power Supply CR24 can supply up to two Charging Racks Master PCR M and Extension PCR E One Master PCR M can support up to 20 Extensions PCR E The Charging Racks are connected see 6 Connection of Charging Rack Master PCR M and Extension PCR E on page 19 with the modular cable delivered with the Extension PCR E Figure 2 022 Master PCR M Master PCR M Extensi...

Страница 7: ... Modules Figure 3 003 Figure 3 Four different examples on how to assemble the PCR Charging Rack The Power Supply module can also be placed apart from the Charging Rack modules Tip When you are planning the location of the modules start to mount them in a height that makes it easy to reach the portables ...

Страница 8: ...Power Supply module must be mounted horizontally and with the clips down Figure 4 002 Figure 4 The Power Supply module must be mounted horizontally 3 4 Mounting the Charging Rack Module Figure 5 UP UP PCR OTHERS UP UP PCR OTHERS 023 Figure 5 The Charging Rack modules must be mounted with the arrow marked UP PCR upwards ...

Страница 9: ... holes by using the dimensions in figure 6 Drill and fasten the modules on the wall with three screws or Remove the covers see 3 6 Removing Covers on page 8 and mount together some of the modules see 3 6 3 Mounting Modules Together on page 10 Hold the mounted modules up against the wall and mark the location of the drill holes Drill and fasten the modules on the wall with three screws Note The pla...

Страница 10: ...8 3 6 Removing Covers 3 6 1 Power Supply Module Figure 7 two slots per module 2 1 005 Figure 7 Removing the cover from the Power Supply module 1 Put a screwdriver onto the slots and slightly bend the cover upwards 1 2 Lift up the cover in the direction of the arrow 2 ...

Страница 11: ...r C Installation Guide PCR Charging Rack 9 3 6 2 Charging Rack Module Figure 8 006 1 2 1 Figure 8 Removing the cover from the Charging Rack module 1 Unscrew the two screws 1 2 Lift up the front in the direction of the arrow 2 ...

Страница 12: ... with two rectangular assembly covers which are provided in the parts bag Place two covers in the adjoining slot 1 Note The Charging Rack modules must be mounted with the marking text UP PCR upwards see figure 5 on page 6 The Power Supply module must be mounted horizontally and with the clips down see figure 4 on page 6 2 Fasten each module on the wall with three screws see figure 6 on page 7 ...

Страница 13: ...Power Supply module 4 Mount rectangular covers which are provided in the parts bag at the openings where there are no adjacent modules 3 see figure 11 below 5 Fasten the cover s angled hooks on the holders 4 6 Snap on the Power Supply module cover 5 7 Fasten the screws in the Charging Rack module cover Figure 11 4 5 3 3 009 Figure 11 Power Supply module mounting of rectangular covers and replacing...

Страница 14: ... mains power supply cable must always be disconnected For safety the covers must always be mounted after an installation The voltage safety cover has to be mounted on top of the voltage connector in the Power Supply module to prevent hazardous situations like electric shock see figure 16 on page 14 4 1 Connection of Mains Power Supply Cable AC 1 Unscrew the voltage safety cover Figure 13 L N V V V...

Страница 15: ...is provided in the parts bag Figure 14 012 Figure 14 Mains power supply cable with cable support holder 3 Cut and strip the mains power supply cables 4 Connect the mains power supply cable onto the indicated positions on the connector see figure 15 Figure 15 L N V V V V OUTPUT IN FG 100 250 V AC 013 Figure 15 The mains power supply connection ...

Страница 16: ...r on its position 1 fasten it with one screw 2 see figure 16 IMPORTANT To prevent hazardous situations like electric shock the voltage safety cover must always be mounted before the power is switched on Figure 16 L N V V V V OUTPUT V ADJ IN FG 014 1 2 2 Figure 16 Mounting of the voltage safety cover ...

Страница 17: ...ight around the sharp edge of the power supply 1 Secure the mains power supply cable with two screws 1 which are provided in the parts bag 2 Mount the cable support holder at the opening on the Power Supply module closest to where the wall socket is placed 2 Figure 17 015 2 1 1 Figure 17 Securing the mains power supply cable 1 and mounting of the cable support holder 2 ...

Страница 18: ...k 16 Supply Voltage Cable DC The 5 V DC supply voltage cable is pre assembled 1 If possible run the 5 V DC supply voltage cable around the cable support to avoid cable break See figure 18 Figure 18 UP UP PCR OTHERS 017 Figure 18 5 V DC supply voltage cable support ...

Страница 19: ...ck 17 4 3 Connection of Supply Voltage Connector IMPORTANT Power Supply CR24 is the only power supply that can be used together with PCR Charging Rack Connect the 5 V DC supply voltage connector to J3 Figure 19 018 J3 5 V DC GND Figure 19 Position of connector J3 ...

Страница 20: ...ion on page 22 3 Perform a reset by pressing the reset button SW300 see 8 Board Description Master PCR M and Extension PCR E on page 21 Make sure that the Function Indicator indicates Software Download Mode see figure 5 on page 6 4 Open the software Ascom Loader see figure 21below Figure 21 Figure 21 Ascom Loader main view 5 Check the communication settings by Settings Communication Baud rate 1152...

Страница 21: ...CR OTHERS UP UP PCR OTHERS UP UP PCR OTHERS UP UP PCR OTHERS 1 2 1 2 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 020 To From To From To From To From To From To From To From To From To From To From To From To From J401 J405 SW300 F100 F100 F100 F100 F100 F100 J100 J100 J100 J400 J401 J100 J400 J401 J400 J401 J100 J400 J401 J100 J400 J303 SW400 SW402 Master PCR M Extension PCR E Extension PCR E Extension PCR E ...

Страница 22: ...power supply cable to the wall socket 2 Check that each charging slot starts charging by putting a portable in each charging slot The beep only indicates that the portable is placed in the PCR Charging Rack The portable is charged when the LED on the portable is flashing orange 7 1 LED status on the PCR Charging Rack Green steady Up and running Green flashing Starting up Red Reset watchdog Orange ...

Страница 23: ...igure 24 PCR Charging Rack circuit board Connectors J403 For connection to PC for software upgrade J405 A bus only Master PCR M SW300 Reset button only Master PCR M SW402 Address module A bus only Master PCR M SW400 Configuration only Master PCR M J100 Power supply J303 Ethernet J400 J401 Modular connector for connection to or from another Extension PCR E or Master PCR M Fuse F100 4A fuse for prot...

Страница 24: ...used must be set to OFF Section 7 Not used must be set to OFF Section 8 Not used must be set to OFF Switch SW402 Address module A bus Select a proper address by setting the address selector switch SW402 hexadecimally see System Installation On Site Paging System TD 90227GB and System installation Personal Security System TD 90678GB under section Addressing When connecting the A bus to the PCR Char...

Страница 25: ...cription A 2005 12 12 First released version B 2006 09 07 Update with safety instructions and software upgrade C 2007 03 15 Update with FCC compliance TD 92356GB 2007 03 16 Ver C Installation Guide PCR Charging Rack 23 ...

Отзывы: