08 October 2018 / Ver. D

10

TD 93272EN

Installation Guide
Application server

Screw the Application Suite with screws to the 19inch rack as shown below.

Note: 

Screws for fastening the assembly brackets in the rack are not included in 

the delivery.

4.3

Supply Voltage

The Application Suite uses a primary power supply (100-240 V AC). 

• Connect supply voltage to the 100-240V AC jack.

Figure 4. 100-240V AC socket on the rear

4.4

Connections

4.4.1  Ethernet Ports

The Application Suite has a 10baseT/100baseT Ethernet modular jack (RJ45) for 
connection to the network, this port is labelled “ETHERNET”.

The Application Suite has 2 additional jacks (RJ45), labeled Port A and Port B. These are for 
future use.

Figure 5. Detail of the connections on the front

Содержание NISM2

Страница 1: ...08 October 2018 Ver D TD 93272EN Installation Guide Application Suite...

Страница 2: ...which accompany this document Ascom Sweden AB makes no guarantees as to the contents of this document and specifically disclaims any implied guarantees pertaining to fitness for any particular purpose...

Страница 3: ...eneral Information 6 2 1 General 6 2 2 The MAC address 6 2 3 Authentication and Administration 6 3 Description 7 3 1 LED status indications 7 3 2 Operating Modes 7 4 Installation and Configuration 9 4...

Страница 4: ...About this Document This document is used for installation and configuration of the module as well as for administration and troubleshooting Primary target groups The field engineer that installs mai...

Страница 5: ...elevision reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient or relocate...

Страница 6: ...be changed to prevent unauthorized access to the administration pages 2 3 1 Authentication GUI pages on the Application Suite always have this user account admin The admin account with the default pas...

Страница 7: ...module and the management port see 2 in Figure 1 is for direct connection to the module The rear side is used for connecting supply voltage 3 1 LED status indications The LED shows that the Applicati...

Страница 8: ...ication GUI is the web user interface for the software application running on the Application Suite 3 2 2 Boot Mode Placing the module in Boot Mode is performed manually by the user but if the module...

Страница 9: ...low 2 Connect the supply voltage see 4 3 Supply Voltage below 3 Connect the LAN cable to the Ethernet RJ45 jack on the front of the Application Suite 4 Access the module via the web interface see Acce...

Страница 10: ...Application Suite uses a primary power supply 100 240 V AC Connect supply voltage to the 100 240V AC jack Figure 4 100 240V AC socket on the rear 4 4 Connections 4 4 1 Ethernet Ports The Application S...

Страница 11: ...used when the Application Suite has not received a valid and unique IP address or when the IP address has been changed i e if the Application Manager has been moved from one network to another It give...

Страница 12: ...ernet RNDIS Gadget is now installed in Control Panel Hardware and Sound Devices and Printers Device manager Network adapters 4 6 Basic Configuration The Application Suite needs to be configured with b...

Страница 13: ...admin and changeme are the default settings The Status Page will show up first 4 6 2 Changing the network settings 1 Access the Application Suite via the network using the IP address and the config e...

Страница 14: ...g External Pages to the User GUI Up to 3 external URLs can be added to the User GUI These links will appear in the left column of the main screen 1 Access the Application Suite via the network using t...

Страница 15: ...le name e g https www ascom com content dam ascom general brand specific assets logo ascom logo svg The logo URL can be obtained by right clicking on the logo in the web page and copying the URL for t...

Страница 16: ...xxx xxx xxx config 2 Login with user and password 3 Select Configuration Sections to change time settings 4 Select the Time Settings to change the time server and for time synchronization of the Appl...

Страница 17: ...s e g English UNITED STATES OF AMERICA 5 Select the language 6 Click Save to save the settings 4 6 6 Uploading a new language file The language file and online help file can be uploaded to the Applica...

Страница 18: ...ew language after several processing seconds the browser needs reloading of the pages 4 6 7 Downloading existing language files The current language file and online help file can be downloaded from th...

Страница 19: ...via the network using the IP address and the config extension xxx xxx xxx xxx config 2 Login with user and password 3 Select Configuration Sections to change locale settings 4 Select Language 5 Click...

Страница 20: ...with IP address 172 20 154 22 5 Click Save to save the settings IMPORTANT Without the NISM IP address the Application Suite will not be able to receive events 6 Use the browser to start the NISM Advan...

Страница 21: ...ogging and add a destination with the IP address of the Application Suite and with the extension ActivityLogger E g Here the Application Suite has IP address 172 20 154 73 7 Use the browser to start t...

Страница 22: ...ostgreSQL database needs to be configured This needs to be done by the system administrator of the network to which the application suite is connected Note The SAL application in MARi will create tabl...

Страница 23: ...tabase 6 Click Save to save the settings IMPORTANT The postgreSQL database needs to be version 9 6 or higher 4 6 11 Configuring the SMTP settings For configuring a Simple Mail Transfer Protocol SMTP 1...

Страница 24: ...l configuration settings Please write down these settings and re enter them after upgrading To upgrade 1 Access the Application Suite via the network using the IP address and the config extension xxx...

Страница 25: ...d how long it has been running E g here a new version v2 1 0 beta2 is running for 0 hours and 3 minutes 9 Select Configuration Sections 10 Re enter all configuration settings see Basic Configuration o...

Страница 26: ...e If no application is running on the Application Suite or if the application cannot be started the Boot Mode can be used for installing new software If the module detects several major errors for exa...

Страница 27: ...08 October 2018 Ver D 27 TD 93272EN Installation Guide Application Server 6 Related Documents Install sheet TD93267US Data Sheet TD93281EN User Manual TD93222EN...

Страница 28: ...08 October 2018 Ver D 28 TD 93272EN Installation Guide Application Server Appendix...

Страница 29: ...ed on how to upgrade the Application Suite with a new package see Upgrading of software package on page 24 Added is a description for additional settings in the NISM see Changing the IP address of the...

Отзывы: