7.11.5 Environment
This section only applies to the IPBL.
The environment tab gives information power supply and consumption. It also display
temperature and fan status.
1
Select Diagnostics > Environment.
2
The following information is available in the
Power
field:
• Power supply - AC or DC power port.
• Voltage - input voltage.
• Current consumption - total consumption for the IPBL an the connected RFPs.
– Max 4,0 A when supplied with AC power port
– Max 5,2 A when supplied with DC power port
Figure 62.
3
The following information is available in the
Environment
field.
• Temperature - °C
• Fan status - OK, not OK
7.11.6 RFP Scan
This section only applies to the IPBS.
To scan for occupied system IDs of other Ascom IP-DECT systems within the coverage area,
perform an RFP scan following the steps below.
Note:
Executing an RFP scan will terminate all calls on the IPBS.
1
Select Diagostics > RFP Scan
2
Click "Start Scanning"
7.11.7 Service Report
This section only applies to the IPBL.
To download a service report do the following:
1
Select Diagnostics > Service Report.
2
Click "download".
3
Click “Save” and browse where to save the service report.