Ascent Communication Technology AP201CWT Скачать руководство пользователя страница 5

AP201CWT GPON 1 GE + WiFi ONT 

 

 

Solutions Provider for FTTx, RFoG and HFC www. ascentcomtec.com 

Page 5 of 32 

 

 

 

 

Do not place the equipment near flammable or conductive items, high temperatures (such as 
direct sunlight) or in wet conditions, or on a PC chassis, and check that the surrounding 
appliances are stable.

 

 

Check the cable for aging. Check and verify that the AC or DC input voltage is within the 
permissible range of the device and that the polarity of the DC is correct.

 

 

Unless the manufacturer permit, use the type of power indicated on the label and the adapter 
supplied with the product.

 

 

To prevent damage to the product from lightning, make sure that the ground of the power 
outlet and the power adapter is securely grounded. In the thunderstorm, be sure to unplug the 
power and all the connections.

 

 

Equipment input voltage fluctuation should be less than 10%, the power plug, refrigerators, hair 
dryer and iron should not use the same socket.

 

 

To avoid electric shock or fire due to overload of the power outlet, damage to the cord or 
damage to the plug, check the power cord regularly. If damage is found, replace it immediately.

 

 

Please place the device on a flat surface and cannot place items on the device.

 

 

Equipment is easy to produce heat when working, should maintain the appropriate cooling 
space to avoid damage caused by overheating products. The elongated hole on the shell is 
designed for heat dissipation. Keep the ventilation clean and avoid falling from the heat sink 
into the equipment. Otherwise, the equipment may be damaged or fire. Do not spill liquid onto 
the surface of the equipment.

 

 

 

 

Please read the user manual carefully before using the equipment and follow all the 
precautions on the user manual and the product.

 

 

Avoid eye looked at the optical interface directly, so as to avoid the laser beam emitted by the 
interface damage the eyes. Please try to wear safety glasses to effectively protect your eyes 
from damage. It is best to plug in the fiber optic interface jacket when the optical interface is 
not in use.

 

 

Turn off the power when the device is not in use

 

 

Before plugging the power supply, make sure that the power switch is turned off to avoid surge. 
Be careful when unplugging the power supply and the transformer temperature may be high.

 

 

To ensure safety, do not open the enclosure of the device, especially when the device is 
powered up.

 

 

Unplug the power supply before cleaning the equipment. Use a soft dry cloth to clean the 
equipment to avoid the use of liquids or sprays.

 

 

Do not connect this product to any electronic product unless it is instructed by our customer 
engineer or your broadband supplier, as any incorrect connection may cause power or fire 
hazard.

 

Содержание AP201CWT

Страница 1: ...AP201CWT GPON WiFi ONT Quick Reference Guide Revision E...

Страница 2: ...rmission of Ascent Communication Technology is strictly forbidden This document is produced to assist professional and properly trained personnel with installation and maintenance issues for the produ...

Страница 3: ...on 7 2 4 LED Description 8 2 5 Device Connection 8 2 6 Applications 9 3 Login Web Management Locally 9 3 1 Physical Connection of ONU and PC 9 3 2 PC Access the WEB of ONU 10 4 ONU Register Informatio...

Страница 4: ...23 7 3 IGMP Proxy 24 7 4 IGMP VLAN Configuration 24 8 WLAN Configuration 25 8 1 WLAN Basic Configuration 25 8 2 WLAN Password Configuration 25 8 3 WLAN Virtual SSID 26 9 CATV Configuration 27 9 1 Conf...

Страница 5: ...orking should maintain the appropriate cooling space to avoid damage caused by overheating products The elongated hole on the shell is designed for heat dissipation Keep the ventilation clean and avoi...

Страница 6: ...wireless transmission rate up to 300Mbps It has the characteristics of strong penetrating power and wide coverage It can provide users with more efficient data transmission security Dual fiber access...

Страница 7: ...ns Provider for FTTx RFoG and HFC www ascentcomtec com Page 7 of 32 Ambient temperature 0 C to 50 C Relative humidity 10 to 90 non condensing Power adapter input 12 V 1A TX Optical Power 0 dBm to 5 dB...

Страница 8: ...thernet connection is not set up 5 LOS GPON optical signals On Optical power lower than receiver sensitivity Off Optical in normal 6 PON ONU Register On Success to register to OLT Blinking In process...

Страница 9: ...E WiFi ONT Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 9 of 32 1 Local NIC of PC connects to LAN port or ETH port of ONU via wires 2 Set the IP address of PC s local NIC as 192...

Страница 10: ...ows and make sure that PC can ping the management IP 192 168 101 1 of ONU Make sure you can ping the ONU like 3 1 Open a web browser such as IE Firefox or Chrome copy and paste the URL http 192 168 10...

Страница 11: ...com Page 11 of 32 Click the Login button The product basics page appears as follows You can start further configuration Login ONU WEB select Status Internet Info GPON Info view the ONU register status...

Страница 12: ...Remote Mgmt LOID view or configure LOID and password of ONU Home Gateway Unit HGU ONU supports route function so that there are route mode and bridge mode for internet The difference between route mo...

Страница 13: ...We can set this option according to your network plan If there is VLAN in the network for internet we have to check Enable VLAN option If not we needn t check this option which will be VLAN transpare...

Страница 14: ...201CWT GPON 1 GE WiFi ONT Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 14 of 32 After configuring the parameters of PPPoE WAN connection as above click Apply to finish the settin...

Страница 15: ...nsparent mode Vlan ID Configure this option according to our network plan MTU The default is 1500 we have to change to lower MTU such as 1400 if we can ping the DNS but not access the website via WEB...

Страница 16: ...201CWT GPON 1 GE WiFi ONT Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 16 of 32 After configuring the parameters of DHCP WAN connection as belows click Apply to finish the settin...

Страница 17: ...t check this option which will be VLAN transparent mode Vlan ID Configure this option according to our network plan MTU The default is 1500 we have to change to lower MTU such as 1400 if we can ping...

Страница 18: ...1CWT GPON 1 GE WiFi ONT Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 18 of 32 After configuring the parameters of Static IP WAN connection as below click Apply to finish the sett...

Страница 19: ...or Internet we have to check Enable VLAN option If not we needn t check this option which will be VLAN transparent mode Vlan ID Configure this option according to our network plan MTU The default is 1...

Страница 20: ...ish the setting Login ONU WEB select Status Internet Info IPv4 Status In here we can view WAN connection status check the route WAN connection if it gets an IP address and Bridge WAN connection if it...

Страница 21: ...r Enable or disable ONU DHCP Server function Start IP address End IP address Configure the IP address interval that allocated to the terminal The address interval must be on the same network segment a...

Страница 22: ...of 32 After configuring the parameters of LAN address as above click Apply to finish the setting Login ONU WEB select Status LAN WLAN WLAN Status View client that access via wireless WIFI As follows...

Страница 23: ...cording to 6 2 and select Other in service mode After configuring the bridge WAN connection The configuration related to other multicast protocols and multicast VLAN can refer to the following 7 2 7 3...

Страница 24: ...function and click Save button to finish the setting as follows Note Normally IGMP Proxy would be used in route mode and carrying Multicast IPTV service because the ONU would be acted as multicast ag...

Страница 25: ...owadays it doesn t support to set as Chinese SSID name Bandwidth It is best to select 20MHz because many PC don t support 40MHz Sometimes PCs can t connect to the WIFI if we select 40MHz or 20MHz 40MH...

Страница 26: ...Apply button to finish setting Login ONU WEB select Internet WLAN Config WLAN Config and then click Virtual SSID button to enter Virtual SSID page We can enable some of virtual SSID set band and name...

Страница 27: ...ptical machine parameters through the ONU s WEB Select Management CATV conifg CATV config In this page we can enable or disable CATV port and configure the parameters according to your requirement Aft...

Страница 28: ...e networks ONU as TR069 remote management of the client need to do the following settings Firstly refered to 5 1 set a Route WAN connection with Service mode as TR069 which is used to act as a channel...

Страница 29: ...ONU WEB select Management Wan Access Control Wan Access Control In this page we can enable or disable the ping remote access and WEB remote access of ONU Login the ONU WEB Select Management Device Re...

Страница 30: ...ct to WAN connection Login the ONU WEB Select Management Firmware Upgrade Firmware Update Click to select firmware file click upgrade button to upgrade the ONU After the application the device is upgr...

Страница 31: ...1 GE WiFi ONT Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 31 of 32 Login the ONU WEB Select Management Device Device Reboot Click Save Restart Restart the device immediately aft...

Страница 32: ...INA USA Unit 1907 600 Luban Road 2710 Thomes Ave 200023 Shanghai CHINA Cheyenne WY 82001 USA Phone 86 21 60232616 Phone 1 203 816 5188 EUROPE VIETNAM Pfarrer Bensheimer Strasse 7a 15 F TTC Building Du...

Отзывы: