For Beaver Die-Head 1/2"-2"
[Removal]
(1)
Remove the Location Plate. Pull locking lever toward “A” to open dies.
Slide cam plate fully toward “B”. (fig.19)
(2)
When the Die-Head is lowered, pull out Dies Nos. 1 and 4 from above.
(3)
Lift and remove the Die-Head and pull Dies Nos. 2 and 3 downward.
[Installation]
(1)
Remove the Location Plate. Pull locking lever toward “A” to open dies.
Slide cam plate fully toward “B” and remove dies. (fig.19)
(2)
Insert Dies with the same number as that of Die-Head until click sound is heard.
Make sure the numbers of Die-Head and Dies show on same side. (fig.20)
(3)Slide cam plate toward “C” until a click sound is heard from locking lever. (fig.21)
19
・
Wear gloves to avoid cutting hands by the Dies.
・
Proper threading cannot be achieved unless the number on the Die-Head slot
matches that of the Dies.
〈
19
〉
〈
20
〉
〈
21
〉