ASA Electronics iN-Command NCSP3 Скачать руководство пользователя страница 1

RV CONTROL AND MONITORING SYSTEM

Patent # (D776,068)

Patent # (D762,644)

Patent # US 9,679,735

NCSP3

Installation and Operation Manual

Содержание iN-Command NCSP3

Страница 1: ...RV CONTROL AND MONITORING SYSTEM Patent D776 068 Patent D762 644 Patent US 9 679 735 NCSP3 Installation and Operation Manual...

Страница 2: ......

Страница 3: ...njury or property damage Operate only when you have a clear line of sight Do not operate any moving parts including but not limited to awnings jacks and slides unless you have a clear line of sight to...

Страница 4: ...ROTECTION 11 SETTINGS 11 Text Editing 11 Scroll List Editing 13 Triggers 14 Generator Fuel 14 Alarm Inputs 14 Passcode 14 Set Passcode Timer 15 Change Passcode 16 Clear Passcode 16 MOBILE DEVICES 17 P...

Страница 5: ...and Hydraulic Slides Control Jacks non automatic function 4 Programmable Auxiliary 12V Triggers 4 Alarm Inputs 12V Monitor Battery Voltage with Low Voltage Alert Auto Generator Start Precautions Use t...

Страница 6: ...lecting the Mounting Location Select a mounting location taking care to avoid the following Places exposed to heat radiating appliances such as electric heaters Adjacent to other equipment that radiat...

Страница 7: ...NCSP3 6 WIRING The wiring diagram depicts all the wiring connections required for proper operation of the unit BODY CONTROL MODULE BCM CONNECTIONS...

Страница 8: ...Stop time Awings Awning Light No Yes Awning 1 In Out Awning 2 In Out Slides Hydraulic In Out Slide 1 In Out Slide 2 In Out Slide 3 In Out Slide 4 In Out Slide 5 In Out Lights Light Group 1 No Yes Lig...

Страница 9: ...ed the iN Command will lock down all motorized functions The Display Commander DC and mobile devices will also display Travel Lock Engaged and the affected buttons will cease to activate The lights wa...

Страница 10: ...s The right switch controls the slides To use the override switches locate the switch needed to actuate the desired component Rotate the switch underneath the rocker switch to select the motor Press u...

Страница 11: ...ter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co located or operating in conjunction with any other antenna or transmitter No change to the...

Страница 12: ...erties from momentary to latch See the status of iN Command Connect devices with Bluetooth Change the passcode Reset the floor plan Control the brightness of the DC screen View IN Command s Legal docu...

Страница 13: ...oard to edit the name then press Save 2 Press Edit to enter Edit page 3 Select the function to edit Note Editing the text on the DC will not change the text on a device s App 4 Long press the intended...

Страница 14: ...NCSP3 13 3 Select the funcition to edit 2 Press Edit to enter Edit page Scroll List Editing 1 Select Settings 4 Use the Up and Down arrows next to the function to move the item in the list...

Страница 15: ...d devices need to be correctly wired to the BCM to function Triggers In the Generator Page Gasoline or Propane can be selected for the fuel type Generator Fuel Alarm inputs can added to the system Not...

Страница 16: ...asscode to enter passcode setup 2 1 Enter the correct passcode to proceed 3 The passcode setup window will open Set Passcode Timer Press Set Timer select the idle time to activate the passcode protect...

Страница 17: ...e to clear the passcode This will restart the App take the user to the End User License Agreement and have the user setup a new passcode 1 Press the Change Passcode button to change to a new passcode...

Страница 18: ...paired to iN Command at one time but only 1 iOS and 3 Android devices are able to be actively paired meaning 3 Android devices and 1 iOS device can all actively control the iN Command functions To use...

Страница 19: ...obile Device to DC 1 Enable Bluetooth in the system settings of the mobile device 2 From the DC Home page select Settings 2 1 Select the Bluetooth tab 2 2 Select Pairing to pair devices and view curre...

Страница 20: ...obile device in the Unpaired Device list Select the device by pressing it 2 4 A Popup with the device name will apear on the display Pass Pair 2 5 A Bluetooth Pairing request will appear on the DC and...

Страница 21: ...isplayed in the Paired Devcies list on the DC 2 9 The DC will be displayed on the mobile device list in the format JENSENDCXXXXX Press the DC on the mobile device to connect with it 2 10 The mobile de...

Страница 22: ...NCSP3 21 4 Reset Floor Plan Press the Reset button in the Menu page to load the floor plan configuration from the DC The current settings will be lost replaced...

Страница 23: ...page shows information of current active Bluetooth devices To disconnect a handheld device press Disconnect or simply shut down the device s App This function is used to disconnect a device that is no...

Страница 24: ...ge the fan speed and change the flow 1 Select the desired Zone Press the Mode button to switch to Cool mode 2 Use the Set up and down arrows to set the desired temperature for the zone 3 Press the Fan...

Страница 25: ...button to switch between Off Low High and Auto Off is not available in Electric Heat Source Auto Mode will automatically switch between Cool and Heat modes to reach the desired Set temperature Heat M...

Страница 26: ...bottom right corner of the HVAC home screen to enter the Schedule page HVAC Schedule AUTO GENERATOR START 1 Press the Generator icon 2 Press the Manual button to switch to Auto and activate Auto Gen...

Страница 27: ...mes If it fails to start after the third attempt the system will turn off the Auto feature and display a Check Generator fault 4 If the generator is started the system will run the generator for 60 mi...

Страница 28: ...the Generator and HVAC scheduling functions 1 Select Settings Date Time 2 Press Date Time 3 In the Date Time page press the Edit tab to adjust the date and time 4 Use the Calendar to select the Date a...

Страница 29: ...nd BCM Versions Software updates include floorplan redesigns and App version updates The system will look for specific file names for software updates File name NCSP3 DC VXXXX zip DC OS update xxxx is...

Страница 30: ...NCSP3 29 7 Framework Update Press Update 8 Press OK to continue 6 Press the DC Version to update the DC OS sytem Press UPDATE 9 Press the BCM Version to update the BCM system Press Updae...

Страница 31: ...lan to select a floor plan Press Load to select the floor plan If a software update is needed go to http www asaelectronics com in command If there is a software issue Call ASA Electronics Technical S...

Страница 32: ...ct System Reset in the Settings page 3 Select on of the two options Floor Plan of Factory to restore to a previous state Current settings will be lost a Floor Plan restores to previous floor plan sett...

Страница 33: ...32 TOUCH SCREEN CALIBRATION 1 Select Settings 2 Select Calibartion 3 To calibrate the Touch Screen select Set Follow the instructions The DC will restart after calibration 4 Touch the center of the c...

Страница 34: ...nks to set resistor reference value for every tank SYSTEM CALIBRATION From the admin page the App Date can be deleted the Generator Hour Meter can be set and the Water Tanks can be calibrated 1 From t...

Страница 35: ...g and troubleshooting purposes Should there be a calibration issue call ASA Electronics Technical Support at 1 877 845 8750 or email them at info asaelectronics com 8 Press the App Date Delete button...

Страница 36: ...of the DC Shut off all power to the DC and BCM Reconnect power wires to the DC Return power to the DC and BCM Press Rest button on the BCM Awnings do not move Check for 12VDC on Pin 88 Ensure the rela...

Страница 37: ...NCSP3...

Страница 38: ...NCSP3...

Страница 39: ......

Страница 40: ...www jensenrvdirect com 2016 ASA Electronics LLC MA 1705001 1R...

Отзывы: