background image

Arzel

®

 Zoning Technology, Inc.

RegiDamper™ Installation Instructions

Application

The Arzel

®

 RegiDamper™ is used where the branch ducts are inaccessible in finished ceilings or 

in slabs, which prevent the use of the original Arzel

®

 EzySlide™ dampers.  The RegiDamper™ is 

installed in the register boot just behind the register and is operated by a low pressure air and 

vacuum pump (contained in the Arzel

®

 panel) by way of a 1/4 inch plenum rated Dekoron (

UL 

Rated

) tubing.

Installation Preparation

• 

Remove all registers and fit damper assemblies into boots with tubing connection facing

 

into the duct opening (see fig. 1-a).

• 

Once damper fit is verified, remove dampers from boot.

Fig 1-a: Inserting RegiDamper™

© Copyright 2004 Arzel Zoning Technology, Inc. All Rights Reserved

U.S. and Foreign Patents and Patents Pending

fig. 1-a - Fitting damper into boot

  • 

Cut an opening in the main trunk large enough to view the take-offs of the runs you are zoning

 

with RegiDampers.  Locate the opening as close to the take-offs as possible.  Tape the cut

 

edges of the opening with duct tape to prevent cutting yourself.