Command Line Interface
Diagnostics and Identification Commands
STATE
32
www.arwestcom.com
3.5.2. STATE
The STATE command is used to check the state of the wireless link, the unit in the link, and the
alarm control lines. To specify a radio unit (local or remote), the CONNECT command must be
used in prior of STATE command using.
STATE [Parameter Name] [Parameters List] [/?]
The STATE command without Parameter Name indicates all values:
TTL_IN1 = 0
TTL_IN2 = 1
RSSI = -110 dBm
BER = < 2.3E-5
FREQ = 140.000000 MHz
CHAN = 10
TEMP = 70C
SYNC = 1
MODE = FIXED
Note:
The indicated receive signal strength (RSSI) is equal to -147 dBm if there is no signal received
from transmitter.
Parameter Name
Parameter List
TTL1
0/1 – State of TTL_IN1 line
TTL2
0/1 – State of TTL_IN2 line
RSSI
-52 to -116 dBm – Indicates the Receive Signal Strength in dBm
BER
1.0E-6 to 9.9E-3 – Indicates the BER level
FREQ
406.000000 to 470.000000 MHz – Displays the central frequency of the
operating channel
CHAN
1 to 9601 – Displays the selected or currently scanned frequency channel
TEMP
-30°C to 100°C – Displays the temperature inside of enclosure
SYNC
1 – Indicates the established link, 0 – if link is not established yet
MODE
AUTO – Indicates Automatic scanning mode
FHOP – Indicates Frequency hopping mode
FIXED – Indicates that the radio modem is working on fixed channel