![ARUSNAVI ELECTRONICS ARNAVI 5 Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/arusnavi-electronics/arnavi-5/arnavi-5_user-manual_2979438046.webp)
USER MANUAL [1.4]
Page 46
ATTENTION:
WHEN USING THE CAN INTERFACE, THE CAN EXT MODES OF THE
INTERFACES RS232 AND RS485 MUST BE DEACTIVATED
2.4 CAN INTERFACE
Internal support of the CAN bus according to the standard J1939 Protocol, without using an external
CAN module, is envisaged for the user’s convenience.
The connection is made to pins 10 (L) and 22 (H) of the main connector of the device.
The transmission rate is 250 kbps.
For correct operation, it is necessary to set the number of the Can program – 3 in the tracker settings.
In the section ‘Package structure’ it is necessary to mark the necessary parameters to be transmitted
to the server.