8.5. Sequence Management
Hold [Sequencer] to view the sequence editing features, then use [Assign 1-6] to select the
desired option. These are described in the following sections.
8.5.1. Copy current sequence
Hold [Sequencer] and press [Assign 1] to copy the current sequence into a temporary buffer.
You can then use the Paste Sequence feature to transfer the sequence to a different patch.
8.5.2. Paste sequence
Hold [Sequencer] and press [Assign 2] to paste some of the contents from the temporary
buffer into the sequence memory of the current patch. This option only pastes the notes
from the sequence, not the automation data. This will replace the note data of the current
sequence with the contents of the temporary buffer.
8.5.3. Paste sequence and automation
Hold [Sequencer] and press [Assign 3] to paste the entire contents of the temporary buffer
into the sequence memory of the current patch. This option pastes both the notes and the
automation data from the sequence. This will replace all of the data of the current sequence
with the contents of the temporary buffer.
8.5.4. Clear current sequence
Hold [Sequencer] and press [Assign 4] to clear the current sequence.
8.5.5. Erase notes
Hold [Sequencer] and press [Assign 5] to erase only the notes inside the current sequence.
The Modulation tracks will not be affected.
8.5.6. Erase automation
Hold [Sequencer] and press [Assign 6] to erase only the Modulation tracks inside the current
sequence. The note data will not be affected.
66
Arturia - User Manual PolyBrute - Sequencer Mode
Содержание PolyBrute
Страница 1: ...USER MANUAL...