1. Electric Specifications 

Model 

T6K T6KS T10K T10KS 3T10KS

3T15KS 

3T20KS 

Rated capacity 

6KVA/4.2KW

10KVA/7KW 15KVA/10.5KW 

20KVA/14KW

Input 

Voltage 220VAC 

380VAC/220VAC 

Frequency 50/60±4 

Hz 

Power factor 

0.98 

0.95 

Phase wire 

1 phase 3 wires   

3 phase 5 wires 

Maximum current 

32A 

50A 

50A 

75A 

100A 

Output 

Voltage 

208/220/230/240VAC

±

1 % 

Phase wire 

1 phase 3 wire 

Battery 0.1 

Frequency 

stability 

Utility power  Synchronize with the utility power (±4HZ) 

Instantaneous response 

<5% (50% - 100% 

  50% linear load transformation)   

Waveform distortion 

<2% (linear load)

<6% (RCD load) 

Overload

Line mode

 

105%<Load<130%: Alarm and Transfer to Bypass after 10min 

Load>130%: Alarm and Transfer To Bypass after 1sec 

Overload

Bypass mode

105%<Load<130%: Alarm

Input Breaker May Trip 

Load>130%: Alarm

Input Breaker May trip

and Cut Off Output after 1min

Overload

Battery mode

105%<Load<130%: Alarm and Cut Off Output after 10sec 

Load>130%: Alarm and Cut Off Output after 1sec 

Efficiency (full load) 

88% 

Transfer time 

Line mode to Battery mode Zero interruption 

Battery mode to Line mode Zero interruption 

INV mode to Bypass mode Zero interruption 

Bypass mode to INV mode Zero interruption 

Other SPEC

 

Noise 

55dB 

60dB 

Temperature 

0°C – 40°C

No condensing 

Altitude 

0 – 1000m 

Humidity <95% 

Warning device 

Double warning with BUZZER beeping and LCD prompt 

Communication interface 

RS232

AS400

RS485

SNMP 

Weight 

90 35 93 38  39 

55 

55 

Dimension W*D*H (mm) 

260mm×717mm×570mm 

 
 
 
 

Содержание 3T10KS

Страница 1: ...to Bypass after 10min Load 130 Alarm and Transfer To Bypass after 1sec Overload Bypass mode 105 Load 130 Alarm Input Breaker May Trip Load 130 Alarm Input Breaker May trip and Cut Off Output after 1m...

Страница 2: ...S voltage 345V 5V BUS voltage 345V 5V Difference between the BUS voltage absolute value 5V Balance voltage zero load 500mV Charging voltage 273V 1 If the above data exceed the electric specification r...

Страница 3: ...3 2 Circuit block diagram Circuit block diagram the dashed indicates the charging board of the long backup time model and the real line indicates the charging board of the standard model...

Страница 4: ...the MOSFET is off the primary stored energy 1 2Llp2 is delivered to the secondary to supply load current and replenish the charge on output capacitors that they had lost when the MOSFET was on This ci...

Страница 5: ...l transfer to the battery mode If disconnecting the batteries from the UPS the UPS will transfer back to the line mode Press the ON button for 0 5 second when the UPS is in the battery mode the buzzer...

Страница 6: ...d voltage of the input utility power will be in the same phase and the power factor is nearly 1 3 4 Inverter circuit Half bridge inverter topology The input of the half bridge inverter topology is DC...

Страница 7: ...The INV mode the inverter output is supplied to the output terminals of the unit via the filter choke the inverter relay contact generally open closed when in INV mode and the load detecting transform...

Страница 8: ...wer goes through noise filter to the pre charging circuit The DC capacitors will be pre charged When the DC voltage on DC capacitor achieve the input AC power peak value then input SCR will turn on Af...

Страница 9: ...model The input of the charger is connected to REC When bypass breaker on and IP SCR on the charger will work The charge voltage is 273VDC and constant charge current is 4 2A Adjust the VR1 on charger...

Страница 10: ...the output send to the rectifier on the PSDR board 4 7 CCB only for 3T15KS 3T20KS The CCB common control board is used to connect the PSDR board and the CNTL board It may help the CNTL board to contr...

Страница 11: ...Note 1 indicates that the jumper is connected 0 indicates that nothing is connected For the pin plugs that are not listed here are not connected pin11 pin12 pin9 pin10 pin7 pin8 pin1 pin2 T6K 0 0 0 1...

Страница 12: ...15 Over temperature Fault 08 Current Un share Fault 16 Inverter Short 09 Error Model 17 Communication Fault 10 SCI RX Error 18 Battery Open 11 Negative Output Power Fault 20 Inverter Relay Short 12 7...

Страница 13: ...n you don t have a discharging resistor perform the maintenance after you have waited for at least 5 minutes and the BUS voltage is less than 10V Otherwise there may be electric shock 4 After you have...

Страница 14: ...X is a digit from 0 to 6 then press the ENTER key output voltage will rise drop a little step 6 INV output voltage setting Type VXXX command XXX is 220 230 240 then press the ENTER key INV output vol...

Страница 15: ...y UPS must be regulated 3 The UPS who have been replaced CNTL PSDR must be regulated again 4 All the commands use capital letters 5 All the above parameter regulation can not be accumulated 6 All the...

Страница 16: ...e NTC on the CN107 of the PSDR board is damaged INV output short The Fault code is 09 The buzzer beeps continuously When the time that the INV output voltage keeps less than 50V and the output current...

Страница 17: ...e output cable and ensure the length of cable is same Error Model The Fault code is 17 The UPS beeps continuously Ensure the model pin plugs in right position SCI RX Error The Fault code is 18 The UPS...

Страница 18: ...normal IP Fuse Open The Warning code is 24 The buzzer beeps every second Check the IP fuse If the IP fuse is damaged replace the fuse immediately 7 5 PCB maintenance 1 Charger board 1 1 Charger board...

Страница 19: ...R340 R339 R341 0 5 6 open 2 PSDR board 2 1 SCR part Item Checked components DVM Function Reference Value Fail Condition 1 F301 F302 0 open A K 1 4M short 2 Q301 Q302 G K 10 short 2 2 Boost part Item...

Страница 20: ...8 Parallel maintenance This UPS has the function of parallel redundancy so if you need to add single UPS to the parallel system refer to the following operating process of adding a new UPS If you need...

Страница 21: ...e slot of the parallel board and screw up the connector Screw the cover board of the parallel port back again 9 Close the input breakers of all of the UPSs including the new UPS in the parallel system...

Страница 22: ...screw the cover board of the parallel port back again 6 Disassemble the cover board of the parallel port located on the UPS that need to be removed and remove the parallel cable and then screw the co...

Страница 23: ...PORT I P L I P N KEY ON BAT BAT BAT BAT BAT BAT O P N GND GND L OTHUPS KEY OFF MAINT SWITCH G G G BYPASS O P EMI I P EMI I P TB O P TB PSDR CHARG PAREL PANEL CNTL REC CHGINPUT G K A G K A G K A E C G...

Страница 24: ...T OTHUPS KEY OFF IP SCR MAINT SWITCH G O P EMI G G BYPASS I P EMI I P TB O P TB L3 L2 L1 PSDR CHARG PAREL PANEL CNTL REC CHGINPUT G K A G K A G K A E C G E C G G K A E C G G K A G K A G K A G K A G K...

Отзывы: