Arton ASD-5 Скачать руководство пользователя страница 1

Instruction manual

 

OPTICAL SMOKE ALARM WITH 2 x 1,5V BATTERIES - 5 YEARS LIFETIME

 

  

    Model: 

ASD-5

 

 

 

 

 

IMPORTANT INFORMATION

Correct usage will ensure you have valuable extra 

time to escape. Every correctly installed smoke 

detector will increase your potential escape time.

• A smoke alarm does not prevent fire.

• Install the smoke alarm in the correct place, if 

possible in the middle of the ceiling.

• Keep the smoke detector out of the reach of  

children.

• Test the unit on a monthly basis and after any 

period of absence. When the alarm does not 

sound, have your smoke alarm inspected by the 

service point or when the smoke alarm is more 

than 10 years old discard the alarm.

 

CAUTION:

 Never test with fire!

• Clean the smoke alarm regularly (once a month) 

using the soft brush of a vacuum cleaner. 

  In addition the smoke alarm can also be cleaned 

using a moist cloth.

• If the detector emits a beeping sound every 40 

seconds, this means that the batteries are nearly 

flat and that you should replace the smoke alarm.

• The lifespan of smoke detectors is 10 years.

• A false alarm can be silenced by pressing the test 

and silence button.

• You can make your Model ASD-5 smoke detector 

less sensitive for ± 10 minutes by pressing shortly 

the test button. The detector will none- 

theless sound the alarm if the quantity of smoke 

is too significant.

Important instructions in case of a fire alarm:

• Plan TWO escape routes and rehearse these with 

all members of the family.

• Agree upon a meeting point where everyone 

gathers in the event of a fire.

In the event of a fire:

• Leave the building immediately together with all  

the members of your family. Gather outside at the 

agreed meeting point.

• Make sure everyone is present.

• Close all doors behind you and never open a 

warm door. If a door is warm, choose an alterna-

tive route.

• In the event of considerable build-up of smoke, 

crawl out of the building keeping as close to the 

floor as possible.

• Wherever possible, breathe through a cloth (pre-

ferably moist), or else hold your breath as much 

as you can. The majority of deaths and injuries 

are caused by smoke inhalation rather than fire 

itself.

• Call the fire department outside.

• Never go back into a burning building.

• Additional information can be gathered at the 

local fire department.

SPECIFICATIONS

Power: 

2 x 1,5V LR03 AAA Alkaline 

Recommended  

batteries:  

- PKCELL Ultra alkaline 1.5V 

   

  LR03. AAA.AM-4  

 

- HUGE SUPER ALKALINE 

   

  1.5V AAA SIZE AM-4 LR03 

 - 

 

DURACELL Plus Power 

Alkaline 1.5V LR03 MN2400

NOTE: The correct functioning of the smoke 

detector is ensured by the use of one of the  

recommended battery.

 

Battery life:   

 5 years under normal  

conditions

Usage: < 

μ

A continue

 

< 70 mA in alarm

Usage temperature:  0ºC tot + 55ºC

Humidity:  

< 93% RH at 40ºC

Sensitivity: Conform 

EN14604

Alarm volume:  

>85dB at 3 meter

&HUWL¿FDWLRQ

$)125(1&( 

CPR 

POSITIONING THE SMOKE DETECTOR

Recommended locations:

Minimum protection: 

A smoke detector on each floor.

 

Maximum protection:  

-  Smoke detector in all rooms (with the exception  

of bathrooms, kitchen, garages, etc.)

-  Heat detectors can be installed in bathrooms,  

kitchens, airing cupboards, utility rooms, etc.  

within 5 metres of a potential source of fire.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• The smoke detector 

should preferably 

be installed in the 

middle of the cei-

ling, at least 50 cm 

from the wall.

• If ceiling mounting 

is not possible to 

mount the detector 

on the wall. A 

minimum of 30 and 

maximum of 50 cm 

from the ceiling. 

(See Figure 3)

• In the case of 

pitched roofs, install 

the smoke detector 

on the sloping wall, 

at least 90 cm  

(measured vertically)  

from the ridge of the roof.

• See minimum and  

maximum protection  

(figures 1 & 2) 

• Ensure that the detector  

can always be reached  

for testing and cleaning.

Never fit a smoke detector:

• In bathrooms, kitchens, shower rooms, garages, 

etc. Places where a smoke detector may go off 

needlessly due to condensation, normal smoke or 

gases. A smoke detector should be fitted at least 5 

metres from such sources of smoke.

• Places where the temperature may exceed 55° C 

or fall below 0° C, e.g. attics, just above a fire- 

place, etc.

• In the vicinity of (or adjacent to) decorative objects, 

doors, sockets, lights, fittings, windows, wall 

 

ventilators, etc. which could mean that smoke 

does not reach the smoke detector. Minimum 

50cm away.

• Surfaces that are usually warmer or colder than 

the rest of the room. Differences in temperature 

can prevent smoke from reaching the detector.

• Adjacent to or directly above stoves or heaters. 

• In very high or difficult to reach places. This makes 

it hard to reach the detector to test or clean it.

0333-CPR-292126

EN14604:2005/AC 2008 

DoP no: 0515

• In very dusty or dirty places. Accumulation of dust 

will prevent smoke from reaching the smoke cham-

ber and in time will lead to a false alarm.

• Within 1 metre of dimmer switches and wiring. 

Some dimmer switches can trigger a fault in the 

detector. 

• Within 1.5 metres of fluorescent lights. Electrical 

impulses can adversely affect the functioning of 

the detector. 

• Outdoors and in spaces where a large number of 

insects are found. Small insects in the unit’s detec-

tion chamber can disrupt the functioning of the 

detector. 

The labels on the rear side of the detector 

 

contain important information.

INSTALLATION

1. Choose a location that satisfies the conditions as 

described in: Positioning the smoke detector.

2. Remove the base plate of the detector by turning 

the base plate anticlockwise (to the left).

3. Mark the mounting holes 

in the base plate and 

drill the holes (use a 6 mm 

drill). If you do not use 

the dowels, then use a 3 

mm drill. Screw the base 

plate securely onto the 

ceiling. Make sure that 

the base plate is tight 

against the ceiling so 

that no air circulation 

above the smoke alarm 

is possible, which could 

impede smoke detection.  

If the opening is too large, this must be remedied 

by the use of a filler.

4. Insert the supplied batteries in the correct man-

ner into the smoke alarm, pay attention to the + 

and -. When activated, the alarm will sound a 

tune.

5. Place the smoke detector on the base plate and 

turn it until the smoke detector clicks into the 

base plate. Turn the smoke detector clockwise  

until you hear a click.

6. Make sure that the smoke detector is working 

properly and that the battery has been activated 

by pressing the test button. A beeping noise that 

stops once the test button is released indicates 

that the smoke detector has been activated and 

is working properly.

ATTENTION: 

The smoke alarm should be covered 

or temporarily removed during renovation work or 

structural alterations. Clean the smoke detector 

with the soft brush from a vacuum cleaner once the 

day’s work is complete, and then replace the 

detector, always testing it by pressing the test 

button once it has been reinstalled.

WARNING: the smoke alarm loses its functionality 

when covered.

FUNCTION TEST  

Test your smoke alarm immediately after instal-

lation, monthly and after a period of absence.

• press the test button for at least 2-3 seconds

‡DORXGVLJQDOZLOOVRXQGDQGWKH/('ZLOOÀDVK

every 0,5 sec., this will stop once the test button 

has been released. 

 

REPLACING THE BATTERIES

•  Remove the batteries from the smoke alarm

•  Place the new batteries in the correct way into 

the smoke alarm. Pay attention to  

the + and the -.

•  Place the smoke alarm back on the base plate 

and test the smoke alarm, see chapter Function 

Test.  

 

FUNCTION AND MEANING OF THE LIGHT 

AND SOUND SIGNALS

Normal situation:

 The red LED light will flash once 

every 320 seconds.

Alarm:

 Whenever the detector detects smoke, it will 

emit a loud pulsing alarm and the red LED light will 

flash continuously (every 0,5 sec.) until the smoke 

has cleared.

Low battery signal:

 A beeping signal every 40 

seconds means that the batteries are nearly flat 

and need to be replaced immediately. This signal 

will sound for 30 days.  

See for the recommended batteries chapter 

SPECIFICATIONS 

Always do the function test when batteries are 

replaced.

Test Button:

 Check that the smoke detector is  

working and that the batteries have been activated 

by pressing the test button for at least 2-3 seconds. 

The smoke detector will give alarm and stop when 

you release the test button. Test the function of the 

smoke detector once per month. When the alarm 

does not sound, have your smoke alarm inspected 

by the service point or when the smoke alarm is 

more than 10 years old discard the alarm.

HUSH Button:

 Your detector is fitted with a pause 

button (see figure 5). This is the same button as 

the test button. Press the pause/test button shortly. 

Your smoke detector will then go into a so-called 

reduced sensitivity mode for + 10 minutes. The red 

LED light will flash every 10 seconds to indicate 

that the Hush button has been activated. The 

detector will nonetheless sound the alarm if the 

smoke is dense or increasing in quantity.

False Alarm:

 Press the test- hush button to stop 

the alarm. (See Hush button)

Pre-alarm status: 

The red LED light flashes every 

second to indicate that the smoke chamber has 

been abruptly contaminated and needs to be 

cleaned. If thorough vacuuming does not help, then 

the contamination is so serious that the detector 

must be returned to the factory.

DUST WARNING: 

3 short beep signals every 40 

seconds means dust in the smoke chamber. 

Remove the batteries and clean the smoke detec-

tor by using the soft brush from a vacuum cleaner.

 

CAUSES OF FALSE ALARM

The smoke detector can be activated by steam, 

condensation, dust, smoke and small insects. 

These are to be prevented as far as possible. See 

section: Never fit a smoke detector. If a detector is 

frequently giving a false alarm, it might be necessa-

ry to install the detector in another location.

 

Maintenance:

• Never allow the detector to come into contact with 

fluids.

• Clean the detector regularly (once a month) using 

the soft brush from a vacuum cleaner. In addition 

the smoke alarm can also be cleaned using a 

moist cloth.

• Repairs must be carried out by the manufacturer.

The detector must never come into contact with 

liquids. 

CAUTION: Do not paint to the detector and do not 

cover it.

LIMITATIONS OF SMOKE DETECTORS

In countries where they are commonly in use, 

smoke detectors have contributed to reducing 

deaths and injuries. Independent bodies have esta-

blished that they were insufficient in around 35% of 

fires, namely in the following situations:

• Where the batteries have been removed or was 

not working. For that reason, you should test the 

unit regularly.

• Where smoke is not able to reach the detector in 

the event of a fire, meaning the unit cannot be set 

off. Examples include a fire on another floor 

where there is no smoke detector, a fire behind 

closed doors, a fire in a chimney or smoke being 

blown away from the detector. For that reason, 

smoke detectors are recommended in all rooms, 

or at any rate on every floor.

• Where the alarm is not heard. A person may not 

be woken by the alarm if that person had consu-

med excess alcohol and/or drugs.

• A few fires are not always detected on time, e.g. 

smoking in bed, if there is no smoke detector in 

the bedroom. In the case of escaping from gas or  

violent explosions, improperly storing explosive 

products and flammable liquids (petrol, paint, 

methylated spirit, etc.), electrical faults, acids, 

children playing with matches (fire).

• The lifespan of smoke detectors is 10 years.

PRODUCT WARRANTY

If used and maintained properly, the manufacturer 

guarantees this product against material and/or 

manufacturing faults for a period of 5 years from 

the original date of purchase by the consumer. 

Exceptions include damage arising from accidents 

or misuse. If the product becomes defective within 

the stated period, then it will be repaired or 

replaced free of charge. Please do not attempt to 

repair the product yourself or tinker with it, which 

will invalidate the warranty.

DOP (Declaration of Performance)

The DoP can be downloaded on our website  

www.fito.eu

INSTRUCTIONS FOR REMOVAL

Do not dispose of your old detector in  

the bin, but rather hand it in to a local  

collection point for small, electrical waste. 

 

MADE IN EUROPE

Manufactured in Europe by: ARTON

6 Prutska str. - Chernivtsi 58008 - UKRAINE

 

 

 

 

 

 

 

 

European supplier:

Fito Products BV

De Langkamp 12a

3961 MS WIJK BIJ DUURSTEDE  

Nederland 

[email protected] - www.fito.eu

2021-5 vers. 1

16

          

RETAIN THESE INSTRUCTIONS FOR FUTURE USE!

These instructions for use contain important information for 

correct installation and use of your smoke detector. Please 

read this information carefully and retain these instructions for 

future use.  

ACTIVATION OF THE SMOKE ALARM:
Insert the supplied batteries in the correct manner into the 

smoke alarm, pay attention to the + and -. When activated, the 

alarm will sound a tune.

Make sure that the smoke detector is working and that the batte-

ries have been activated by pressing the test button for a few 

seconds. The smoke detector will give alarm and stop when you 

release the test button.

&KDUDFWHULVWLFVFHUWL¿HGE\$)125

Ceiling and wall mount

YES

Battery powered

YES

Autonomy 5 years

YES

Individual Alarm Indicator

YES

Alarm silence facility

YES

Suitable for installation in a 

caravan

YES

Option to connect external 

devices

NO

Interconnectable

NO

 

Certified by :  AFNOR Certification

11, rue Francis de Pressensé - F-93571 La Plaine - Saint Denis Cedex

www.afnor.org

kitchen

living room

bathroom

bedroom

hallway

Figure 1 

bedroom

bedroom

bedroom

bedroomr

bedroom

hallway

kitchen hallway

living  
room

basement

Figure 2

Figure 3

Figure 4

Mounting holes :

screw: 3x25 mm 
dowel : 5x30 mm

Figure 5

Test- and 
hush button

LED light 

 

0333

EN14604:2005/AC 2008

Essential characteristics:

Performance:

Nominal activation conditions/sensitivity, response delay (res-

SRQVHWLPHDQGSHUIRUPDQFHXQGHU¿UHFRQGLWLRQV

Passed

Fito Products BV

De Langkamp 12a

3961 MS Wijk bij Duurstede

The Netherlands

16

0333-CPR-292126

Operational reliability:

Passed

Tolerance to supply voltage:

Passed

Durability of operational reliability and response delay,  tempera-

ture resistance:

Passed

Durability of operational reliability, vibration resistance:

Passed

Optical smoke detector, 

alerts you in the event 

RI¿UHRUVPRNHDQGLV

suitable for residential 

buildings.

Durability of operational reliability, humidity resistance:

Passed

Durability of operational reliability, corrosion resistance:

Passed

Durability of operational reliability, electrical stability:

Passed