MaxCore™ MC3000 

Platform AC 

Quick Start Guide

P/N:6806800T89E (February 2018)

Observe ESD-safe measures

• Use either a properly grounded ESD wrist 

strap or make sure that you are working in an 
ESD safe environment.

• Connect to the ESD connector at the rear of 

the system.

2

What’s in the box?

Make sure you receive all items of your ship-
ment:
• One MaxCore™ MC3000 Platform
• One printed copy of 

Quick Start Guide

 (this 

document).

One printed copy

 of Safety Notes Summary.

• Other items that were ordered.

Prepare the installation site

1. Make sure that all environmental and power 

requirements defined in the 

MaxCore™ 

MC3000 Platform Installation and Use

 manual 

are met.

2. Remove all items from the box.
3. Provide the following cables:

– Earth grounding cable with a two-hole lug, 

distance 5/8" behind (15.9 mm) in case of rack 
installation.

– A power input cable for each installed power 

supply with a minimum cross section of 
1mm

2

.

– Twisted pair Ethernet cable for connecting the 

BMC ETH port or any of the other four (4) ETH 
ports of the system.

– USB and/or microUSB cables to connect the 

system's USB ports.

For more information about connecting cables 
and power cords, refer to the 

MaxCore™ MC3000 

Platform Installation and Use 

manual.

Install the system in the 

rack

1. Insert the system into a 19" ANSI rack.
2. Fasten the system to the rack via the inte-

grated chassis mounting flanges using two 
bolts or screws (minimum 6 mm (0.24 inch) 
in diameter) on the left side and two on the 
right side of the system.

5

3

Install PCIE cards

1. Remove the housing cover of the system. 

Press the lock button in the mid of the hous-
ing cover and push the housing cover towards 
the rear of the system. The cover will slide 
backwards and then it can be lifted off the 
system.

Note

: Before removing the housing cover 

ensure that the system is shut down and dis-
connected from AC power.

2. Remove the filler cards or filler panels in the 

PCIE slots, if any.

3. Install the PCIE card(s) in the respective 

slot(s).

4. Fill the empty PCIE slots with filler cards or 

filler panels. A slot adjacent to the component 
side (primary side) of a high power card 
should always contain a filler card for better 
cooling. For more information about PCIE 
card installation, refer to the 

MaxCore™ 

MC3000 Platform Installation and Use 

manual

.

Ground system

1. Connect the rack grounding cable with a 

two-hole lug to the M5 system ground lug 
location on the rear of the system, to the 
right of Slot 15. Torque the system ground 
lug nuts to maximum of 2.5 Nm (22.12 in-
lbs). Use a grounding cable of size 1.25 mm

2

 

for the AC system.

2. Connect the system permanently to the 

earth ground of the building.

6

4

1

When installing or servicing the system 
or accessories, strictly observe the safety 
precautions in the 

Safety Notes Summary

Otherwise, personal injury or property 
damage may occur. Ignoring these 
instructions can void the system war-
ranty. 

Connect to power feed

1. Put on an ESD wrist strap and connect the 

strap to the system by attaching the rear 
ESD jack/ESD snap, if you are not in an ESD 
safe environment.

2. Make sure the external power feeds that you 

plan to attach are powered off and cannot 
be switched on while you are working.

3. Connect the AC International Electric Code 

(IEC) wired connector to the AC power sup-
plies.

4. Turn on the external feed power. The input 

LEDs on the power supplies turns Green.

7

Содержание MaxCore MC3000

Страница 1: ...n the mid of the hous ing cover and push the housing cover towards the rear of the system The cover will slide backwards and then it can be lifted off the system Note Before removing the housing cover ensure that the system is shut down and dis connected from AC power 2 Remove the filler cards or filler panels in the PCIE slots if any 3 Install the PCIE card s in the respective slot s 4 Fill the e...

Страница 2: ... MegaRAC provides the display and a remote connection is established over Ethernet There is no VGA cable connector provided by MaxCore To connect to shelfHost over VGA 1 Connect your PC to the BMC connector and login to MegaRAC as described in Step8 2 Go to Remote Control Console Redirec tion and click VGA Console button When everything is setup correctly a JViewer window will launch displaying VG...

Страница 3: ...Contact your local Artesyn sales executive 13 Connect to SSF on Shelf Host System Services Framework SSF represents the front door entry into MaxCore It provides access to all application relevant resources including the PCIe cards SSF is executed by the shelfHost and is supported by the BMC To connect SSF on shelfHost 1 Unplug the cable from BMC and plug it into the ETH4 connector on the IO Panel...

Страница 4: ...visit http crc portal artesyn com Single Cable for BMC and shelfHost You can connect your PC to BMC and shelfHost with a single cable Ensure that the eth0 interface of the BMC and the ETH4 interface of the shelfHost have IP addresses from the same subnet The factory defaults are 172 26 1 1 for the BMC and 172 26 1 2 for the shelfHost Connect your PC to the ETH4 connector at the MaxCore front and t...

Отзывы: