Functional Description
COMX-P4080-2G-ENP2 Installation and Use (6806800P63B
)
40
4.8
Thermal Management
COMX-P4080-2G-ENP2 provides a thermal management strategy. This includes CPU junction
temperature monitoring.The following diagram shows thermal management strategy:
A thermal diode is integrated in P40x0, which connects to a thermal sensor ADT7411. The CPU
can get the junction temperature via I2C.
When the junction temperature goes up to105
o
C, ADT7411 drives INT# to low, indicates an
interrupt to CPU. A red LED D17 can show the interrupt status.
Figure 4-4
Board Thermal Management
LED
Definition
Definition
Description
D17
INT# signal is active
ON
The CPU temperature
goes up to 105
o
C
OFF
Normal status