8.4.11 Set Payload Communication Time-Out Command
The Set Payload Communication Time-Out command sets the payload communication time-
out value.
2:4
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00
5
Payload Time-out
Payload communication time-out measured in hundreds
of milliseconds. Thus, the payload communication time-
out may vary from 0.1 to 25.5 seconds.
Table 8-35 Get Payload Communication Time-Out Command Description (continued)
Type Byte
Data
Field
Table 8-36 Set Payload Communication Time-Out Command Description
Type Byte
Data
Field
Request Data
1:3
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 1 = 0A, byte 2 = 40, byte 3 = 00
4
Payload Time-out
Payload communication time-out measured in hundreds
of milliseconds. Thus, the payload communication time-
out may vary from 0.1 to 25.5 seconds.
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00
Содержание ATCA-7365-CE
Страница 1: ...ATCA 7365 CE Installation and Use P N 6806800L73N May 2016 ...
Страница 26: ...ATCA 7365 CE Installation and Use 6806800L73N About this Manual 26 About this Manual ...
Страница 36: ...ATCA 7365 CE Installation and Use 6806800L73N Sicherheitshinweise 36 ...
Страница 140: ...BIOS ATCA 7365 CE Installation and Use 6806800L73N 140 ...
Страница 284: ...Replacing Battery ATCA 7365 CE Installation and Use 6806800L73N 284 ...
Страница 287: ......