ARTESYN EMBEDDED TECHNOLOGIES ATCA-7350 Скачать руководство пользователя страница 1

ATCA-7350

Quick Start Guide

P/N:6806800H72C (August 2014)

When installing or servicing the 
module or accessories, strictly 
observe the safety precautions in 
the 

Safety Notes Summary

. Other-

wise, personal injury or property 
damage may occur.

Make sure you receive all items of your 
shipment:
• One ATCA-7350 blade
• One RTM-ATCA-7350
• One printed copy of 

Quick Start Guide

 

(this document)

• One printed copy of 

Safety Notes Sum-

mary

• Any other optional items that you 

ordered

1

What’s in the box?

Observe ESD-safe 

measures

• Use either a properly grounded ESD wrist 

strap or make sure that you are working 
in an ESD-safe environment. 

• Connect your ESD wrist strap to the ESD 

connector at the front or the rear of the 
system.

2

Checking Installation 

environment

• Leave enough space around the cab-

inet. Prevent air blocking of fans and 
provide controlled ambient air at 
shelf air-inlet to ensure sufficient air-
flow and appropriate heat exchange 
in the shelf.

• Consider heat dissipation when you 

choose slots to install blades. If the 
shelf is not fully configured, install 
the blades in scattered slots. Unoc-
cupied slots must be protected with

• appropriate blank filler blades to 

prevent air leaks.

3

Installation of 

RTM-ATCA-7350

4

The following procedure describes the 
installation of RTM-ATCA-7350. It 
assumes that your system is powered on. 
If your system is powered off, you can dis-
regard the blue LED and thus skip the 
respective step. In this case it is a purely 
mechanical installation.
1. Wear the ESD-preventive wrist strap.
2. Take RTM-ATCA-7350 out of the anti-

static package.

3. Fully open the upper and lower ejector 

handles of the RTM.

4. Align the upper and lower sides of 

RTMATCA-7350 with the guide rails 
(the edges of the slot). Slide RTM-
ATCA-7350 along the guide rails until 
the positioning pins of RTMATCA- 7350 
are inserted in the positioning

5. holes in the shelf. The LEDs; OOS LED, 

Blue LED, and healthy LED are on.

6. Make sure that the handles are in the 

open position.

Отзывы: