Figure 28-9 Quick read quad output
0
1
2
3
4
5
6
7
8
9
10
28
29
30
31
Instruction (6Bh)
24-Bit Address
3
2
1
0
23
22
21
CS
CLK
IO0
Mode0
Mode3
40
41
42
43
44
45
46
47
CS
CLK
IO0
0
4
0
4
1
5
1
5
0
4
0
4
1
5
1
7
39
33
34
35
36
37
38
32
IO1
IO1
Dummy Clocks
4
5
IO2
IO3
2
6
2
6
2
6
2
6
IO2
6
3
7
3
7
3
7
3
7
IO3
7
IO Switches from Input to Output
Byte 1
Byte 2
Byte 3
Byte 4
To execute a quick read quad I/I command, set instruction code/length, address/address size, the
second dummy period, continuous read mode/code and enable quad I/O mode. Refer to Figure 28-10
for more information.
Figure 28-10 Quick read quad I/O command
0
4
0
4
1
5
1
5
0
4
0
4
1
5
1
7
2
6
2
6
2
6
2
6
3
7
3
7
3
7
3
7
A32-16
A15-8
A7-0
M7-0
0
1
2
3
4
5
6
7
8
9
10
Instruction (EBh)
CS
CLK
IO0
Mode0
Mode3
11
12
13
14
15
16
17
18
19
20
21
22
23
0
4
0
4
1
5
1
5
2
6
2
6
3
7
3
7
IO Switches from
Input to Output
Byte 1
Byte 2
Dummy
Dummy
IO1
IO2
IO3