AT32F413
Series Reference Manual
2022.06.27
Page 286
Rev 2.00
011: 28.5 cycles
100: 41.5 cycles
101: 55.5 cycles
110: 71.5 cycles
111: 239.5 cycles
Bit 5: 3
CSPT11
0x0
rw
Sample time selection of channel ADC_IN11
000: 1.5 cycles
001: 7.5 cycles
010: 13.5 cycles
011: 28.5 cycles
100: 41.5 cycles
101: 55.5 cycles
110: 71.5 cycles
111: 239.5 cycles
Bit 2: 0
CSPT10
0x0
rw
Sample time selection of channel ADC_IN10
000: 1.5 cycles
001: 7.5 cycles
010: 13.5 cycles
011: 28.5 cycles
100: 41.5 cycles
101: 55.5 cycles
110: 71.5 cycles
111: 239.5 cycles
19.6.5 ADC sampling time register 2 (ADC_SPT2)
Accessible: word.
Bit
Register
Reset value
Type
Description
Bit 31: 30 Reserved
0x0
resd
Kept at its default value
Bit 29: 27 CSPT9
0x0
rw
Sample time selection of channel ADC_IN9
000: 1.5 cycles
001: 7.5 cycles
010: 13.5 cycles
011: 28.5 cycles
100: 41.5 cycles
101: 55.5 cycles
110: 71.5 cycles
111: 239.5 cycles
Bit 26: 24 CSPT8
0x0
rw
Sample time selection of channel ADC_IN8
000: 1.5 cycles
001: 7.5 cycles
010: 13.5 cycles
011: 28.5 cycles
100: 41.5 cycles
101: 55.5 cycles
110: 71.5 cycles
111: 239.5 cycles
Bit 23: 21 CSPT7
0x0
rw
Sample time selection of channel ADC_IN7
000: 1.5 cycles
001: 7.5 cycles
010: 13.5 cycles
011: 28.5 cycles
100: 41.5 cycles
101: 55.5 cycles