INSTALLATION
&
USAGE
MANUAL
FIREPLACE
| MENTOR Hydro
22 |
Page
-
ALARM screen
This screen is displayed when there is one of the following situations:
Failure of the sensor on the top of the boiler (T1). The screen displays
WAW temp. sensor (T1) damaged
. If the sensor is not installed, the alarm is not
activated.
Failure of the sensor on the bottom of the boiler (T2). The screen displays
WAW temp. sensor (T2) damaged
. If the sensor is not installed, the alarm is not
activated.
Failure of the sensor on the water jacket of the fireplace (T3). The screen displays
Fplace temp. sensor (T3) damaged.
Exceed on the limit of the temperature in the water jacket of the fireplace. The screen displays
Too high temp. of the fireplace
The alarm is accompanied by an intermittent acoustic signal, which can be canceled by pressing the CONFIRM (
6
).
key. Also when there is a temperature exceeding alarm, the HC pump automatically starts in order to cool the
fireplace down.
-
Electrical installation
The instructions for connecting are included inside the packaging of the automatic regulator
(Page. 15).
7.
L
IGHTING THE FIREPLACE
The automatic combustion air damper, regulates the combustion depending on the water temperature inside the
tank. This thing allows you to deal only with the lighting and the supplying of the fire with wood.
To form an adequate layer of ash at the base of the fireplace, use 1-2 kg of dry kindling the first time you light it. If it is
possible, constantly maintain a layer of ash with thickness of 2-3 cm at the base of the combustion chamber for added
insulation.
7.1.
Traditional method of lighting
1.
Place 2-4 kindling tablets or 7-10 wrapped newspaper sheets beneath
1-2 kg dry kindling. and light them up.
2.
After 15-20 minutes a thick layer of cinder will be formed in the
combustion chamber and the temperature will rise, which is essential
for the continuation of combustion.
3.
Once the requirement described in
point 2
is met, place more logs,
keeping a distance of 1 cm approximately from one another. The new
wood will begin to burn within 2-3 minutes.
4.
As soon as the fire leaves a thick layer of cinder, you can add more
firewood by repeating steps 3.
Alarm type
Pic. 7.1.1
:Traditional method of lighting
The electrical installation must be done NECESSARILY by specialized staff.
To avoid covering the glass with soot, it is important not to let logs lean against it.