6.3.
General information
-
When the fireplace paint dries
ARTE ® products are painted in spray booth with as more environmentally friendly and ecological
colors as possible.
There is although a possibility that the first few times the fireplace is lighted, the paint emits an odor. Let the fire burn
with intense convection until all traces of gas disappear and there is no longer a smell. The gas is not toxic, but the
room should be well ventilated.
-
Incineration preparation
Prepare sufficient amount of chopped firewood, kindling and torches or branches. Before using the wood it is
recommended to store them in a warm place for a few days.
-
Combustion air intake
Although the fireplace uses external air for combustion, make sure that the room is ventilated adequately when the
fireplace operates with fresh air. When you open the door of the combustion chamber for adding firewood there
should be no pressure difference between outdoor and indoor air in the room, so it is good to keep the door open
for about 1.5cm for 5-6 seconds and then fully open it.
-
Power failure
In case of power failure, the water pump/s does not operate so there is overheating danger of the water in the tank.
For this reason, the control panel stops the combustion air supply, in order the fire to go out gradually and the
temperature of the water in the tank to drop, avoiding overheating, although there is overheating protection
(Chapter. 5, Pic. 5.9.6).
Therefore, it is suggested the connection of the water pumps and the control panel with an
uninterruptible power supply unit (UPS), in order the flow of the water to be prolonged till the fire in the chamber
drops out. It is suggested a pure sine wave UPS with minimum power of 1000VA to be used, which will ensure
uninterruptible operation of your fireplace for approximately 1 hour.
-
Heating during seasonal change or in adverse weather conditions
When there is high humidity or fog, with temperature
s ≥15 °
C, but also during the transitional period between
seasons, it is recommended to light a test fire before normally lighting the fireplace. This will displace the cold, heavy
air that is inside the flue and create the right conditions for optimum smoke dissipation
-
ADF function
The automatic (and adjustable) fume damper [ADF]
(Table 6.2.1, Line 10)
enables you to adjust the damper to
remain open in any position desired, even with the main door closed, in order to ensure adequate convection,
depending on the season.
e.g.
Winter → Towards closed
Spring
–
Autumn → Towards open
To adjust the damper, turn the regulator right to close the damper and left to open it, checking the indicator in order to
calculate its inclination
(Pic. 6.3.1).
Position 1
Position 2-3
Position 4-6
CLOSED DAMPER
INTERMEDIATE
POSITION
OPEN DAMPER
Pic. 6.3.1
IN CASE OF POWER FAILURE. DO NOT OPERATE THE DEVICE WITH THE MAIN DOOR OPEN. OTHERWISE,
THE OVERHEATING VALVE WILL DISPOSE OF THE OVERHEATED WATER AT THE DRAINAGE
.
The air intake must be positioned so as not to allow being covered.