background image

- 1 - 

 

The ART 

SLA-1 Studio Linear Amplifier 

 

TABLE OF CONTENTS 

 

 
Safety Precautions  ................................................................................  2 
Introduction ...........................................................................................  3 
 
Installation .............................................................................................  4 

AC Power Hookup ...............................................................................  4 
Audio Connections  ..............................................................................  4 
Operation Precautions  ........................................................................  4

 

 
Controls and Indicators  ......................................................................... 5 

Power Switch .......................................................................................  5 
Channel Attenuators  ...........................................................................  5 
Signal LED Indicator  ...........................................................................  5 
Clip LED Indicator  ...............................................................................  5 
Protect LED Indicator  ..........................................................................  5 

 
Connections ...........................................................................................  6 

¼” Input Jacks....................................................................................... 6 
XLR Input Jacks  ..................................................................................  6 
Amp Mode Switch  ...............................................................................  7 
Output Binding Post  ............................................................................  7 
SmartFan™ .........................................................................................  7 
Fuse ....................................................................................................  8 
AC Power Input  ...................................................................................  8

 

Ground Lift Switch ...............................................................................  8

 

 
Operation ...............................................................................................  9 
 
Warranty Information  ..........................................................................  11 
 
Service ..................................................................................................  12 
 
SLA-1 Specifications ...........................................................................  13 

Содержание SLA-1

Страница 1: ...Precautions 4 Controls and Indicators 5 Power Switch 5 Channel Attenuators 5 Signal LED Indicator 5 Clip LED Indicator 5 Protect LED Indicator 5 Connections 6 Input Jacks 6 XLR Input Jacks 6 Amp Mode...

Страница 2: ...t obstruct the ventilation slots or position the unit where the air required for ventilation is impeded If the unit is to be operated in a rack case or other furniture ensure that it is constructed to...

Страница 3: ...face quickly and easily delivers the power you need for professional and project studio monitoring FEATURES Studio Linear Amplifier Extremely Low Noise Discrete Linear Design 100 Watts Channel 8 Ohms...

Страница 4: ...ufactured for use outside the United States of America have been modified to comply with the required electrical specifications AUDIO CONNECTIONS Audio connections to and from the SLA 1 are balanced X...

Страница 5: ...he attenuators are calibrated in dB SIGNAL LED INDICATOR This LED indicates that a signal is present The LED will glow when the amplifiers output signal is within approximately 30dB of full scale CLIP...

Страница 6: ...han 20 feet For cable runs under 20 feet the option may be preferable You may also use the two different types of input cables to jump a parallel connection to another amp For example connect an XLR c...

Страница 7: ...rew the red and black caps on the binding posts don t completely remove Insert the spade connector into the binding post and tighten the caps down on the spade connector Be sure the wire connected to...

Страница 8: ...ge of your amplifier Serious damage could result GROUND LIFT SWITCH This switch is used to disconnect the internal ground signal from the chassis case ground This may be used to reduce 60Hz noise hum...

Страница 9: ...gain controls are turned down to their lowest level full counter clockwise Turn the amp on then slowly turn the input level up Use your front gain controls to regulate the output volume Be sure not t...

Страница 10: ...ar mounted variable speed fan provides extra cooling of the amplifiers internal circuitry as needed If in the unlikely event the heatsink should reach 90 degrees Celsius the amplifier will mute until...

Страница 11: ...sions This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs This warranty is void if the serial number is altered defaced or...

Страница 12: ...ns regarding technical assistance or repairs Customer Service hours are 9 00 AM to 5 00 PM Eastern Time Monday through Friday 4 Pack the unit in its original carton or a reasonable substitute The pack...

Страница 13: ...table to 2 ohms Minimum Load Impedance Mono 8 ohms normal operation stable to 4 ohms CMRR 60dB typical 1kHz Frequency Response 10Hz to 40kHz 5dB Hum and Noise 100dB below clipping Total Harmonic Disto...

Отзывы: