The Pro Channel was designed and manufactured in the United States of America. 
 

Applied Research and Technology, Inc. 

 

(716) 436-2720 (Phone) 

 215 

Tremont 

Street     (716) 

436-3942 

(FAX) 

 

Rochester, NY 14608 USA 

We’re on-line! 

For Product information, questions, applications, tips, answers and general discussion 
with A R T employees look for A R T on the Internet.  Email us at [email protected]   
Check out our Web Site at: http://www.artroch.com  

Warranty and Service Information 

Limited Warranty 

Applied Research and Technology, Inc.  (A R T) will provide warranty service for this 
unit in accordance with the following warranty statement.  A R T warrants to the 
original purchaser that this product is free from defects in workmanship and materials 
for a period of three years from the date of purchase.  A R T will, without charge, repair 
or replace, at its option, defective product or component parts upon prepaid delivery to 
the factory service department or an authorized service center, accompanied by proof of 
purchase date in the form of a valid sales receipt.   

EXCLUSIONS:

 This warranty does not apply in the event of misuse or abuse of the 

product or as a result of unauthorized alterations or repairs.  This warranty is void if the 
serial number is altered, defaced or removed. 
A R T reserves the right to make changes in design and make additions or 
improvements upon this product without any obligation to install the same on products 
previously manufactured.  A R T should not be liable for any consequential damages, 
including without limitation damages resulting from the loss of use.  Some states do not 
allow limitation of incidental or consequential damages, so the above limitation or 
exclusion may not apply to you.  This warranty gives you specific rights and you may 
also have other rights, which vary, from state to state.  For products purchased outside 
the United States, service will be provided by an authorized distributor of Applied 
Research and Technology, Inc.  products. 

- 22 - 

Содержание Pro Channel

Страница 1: ...HNOLOGY Inc 215 TREMONT STREET ROCHESTER NEW YORK 14608 USA 716 436 2720 Voice 716 436 3942 Fax Internet http www artroch com E mail art art com Pro Channel Professional Tube Mic Preamp Compressor Equ...

Страница 2: ...Pro Channel PROFESSIONAL TUBE MIC PREAMP COMPRESSOR EQUALIZER USER S GUIDE...

Страница 3: ...S INDICATORS 7 PREAMP CIRCUIT 7 Gain Control 7 Gain Switch 8 Phantom Power Switch 8 Phase Switch 8 Tube Drive Gain Reduction Display 9 Preamp Output 9 COMPRESSOR CIRCUIT 10 Threshold Control 10 Ratio...

Страница 4: ...VU Meter 15 VU Meter Switches 15 Power 15 REAR PANEL CONNECTIONS 15 INPUT AND OUTPUT CONNECTIONS 15 Input 16 Output 16 LOOP INSERTS 16 Preamp Compressor Loop 16 Compressor EQ Loop 16 Loop Connections...

Страница 5: ...s A solid state input circuitry Both electro optical and variable mu compressor designs Tube based semi parametric four band equalization with selectable frequency ranges and Q Three hand selected tub...

Страница 6: ...ign Notes The Pro Channel is a multi purpose tool for audio engineering and recording Enclosed in a two rack space 2U chassis are three independent circuits featuring a tube based analog preamplifier...

Страница 7: ...rotect the unit during initial shipment Please retain this carton for use in transporting the Pro Channel or in the unlikely event that you need to return your Pro Channel for servicing AC Power Hooku...

Страница 8: ...o produce a thump on power up and power down Note Like all tube based equipment the Pro Channel needs to warm up before being used Allow one to two minutes for the tubes to reach proper operating temp...

Страница 9: ...leaking from a tire when phantom power is disconnected but some can make some very nasty low rumbles and whines as well Another Note MOST dynamic microphones should not be affected or damaged if they...

Страница 10: ...g for a range before it turns into a distortion box After some use you ll find that the sweet spot of the Pro Channel is when this light flashes fairly regularly and the top red LED flashes occasional...

Страница 11: ...ery mild and musical compression ratio which is ideal for smoothing all types of signals At its maximum position the compression ratio is greater than 10 1 This is typically called hard limiting as it...

Страница 12: ...is to remind you that the compressor is out of the signal path but still gives you an indication how much compression will result when the compressor is engaged Use the Bypass switch when setting the...

Страница 13: ...s as range of 12dB Two ranges are selected with the Low Shift Switch 40Hz or 120Hz 40Hz is great for enhancing sub low frequencies such as those in bass guitars and kick drums Cutting 40Hz can also he...

Страница 14: ...h The Hi Mid Shift x 10 switch determines the range over which the Hi Mid Frequency control will cover In its out position the range is set at 200Hz to 2KHz In its in position the range is set at 2KHz...

Страница 15: ...qualizer circuit to enable you to remove it from the signal chain When set to its in Bypass position signal is allowed to pass from the compressor circuitry to the output tube section with no equaliza...

Страница 16: ...hand switch is set to Output the left hand switch has no effect Another Note The internal level monitoring points correspond to the level at the Send jacks of the two insert loops If you are using eit...

Страница 17: ...ack is inserted The loops may also be utilized to re patch the compressor and equalizer circuits in a different order i e signal flow preamp to equalizer to compressor Preamp Compressor Loop A loop is...

Страница 18: ...microphone instrument or line level source To use the Pro Channel as a mic or line preamplifier only simply press the Bypass switches to bypass the compression and equalizer circuitry Plug a microphon...

Страница 19: ...rument can be fixed by simply isolating the bad frequency and pulling it out After you determine approximately where the problem area is in the instrument highs lows mids isolate the track and boost o...

Страница 20: ...ever be sure to have output and monitoring levels turned DOWN before testing the sound Remember you have a great amount of gain available in the Pro Channel Grounding Connecting several pieces of equi...

Страница 21: ...Block Diagram 20...

Страница 22: ...s 3sec program dependent Maximum Compression 30dB optical 23dB vari mu EQ Frequency Bands Low Shelf 40Hz 120Hz selectable Low Mid Sweepable 20Hz to 200Hz 200Hz to 2KHz Shift out in Low Mid Q Wide Narr...

Страница 23: ...paid delivery to the factory service department or an authorized service center accompanied by proof of purchase date in the form of a valid sales receipt EXCLUSIONS This warranty does not apply in th...

Страница 24: ...ization RA number 4 Pack the unit in its original carton or reasonable substitute The packing box is not recommended for a shipping carton Put the packaged unit in another box for shipping Print the R...

Отзывы: