Copenhagen Blind Wall Controller

Productno: AACPH-RC1-EU 

 
The  Wall  Controller  is  a  multi-function  button  which  is  able  to 
control  the  position  of  a  blind  and  switch  appliances  on/off.    The 
Wall Controller consists of a wall bracket and a portable
The portable controller has an integrated magnet which 
user the possibility to place it in the wall bracket or on any metallic 
surface.  This  product  can  be  included  and  operated  in  any  Z
Wave

TM

 network with  other Z-Wave

TM

 certified devices from other 

manufacturers and/or other applications. 
 
The  rotation  function  to  control  position  of  blind  works  when 
controller  is  fitted  upright  or  stick  on  the  wall
situations the controller will work only as a binary switch.
 

Please provide a 5 DVC voltage through Micro USB Port to 
wake the device up before the first using. 

 
 

Copenhagen Blind Wall Controller 

function  button  which  is  able  to 

control  the  position  of  a  blind  and  switch  appliances  on/off.    The 

portable controller. 

The portable controller has an integrated magnet which gives the 

in the wall bracket or on any metallic 

surface.  This  product  can  be  included  and  operated  in  any  Z-

certified devices from other 

to  control  position  of  blind  works  when  the 

is  fitted  upright  or  stick  on  the  wall,  in  all  other 

as a binary switch. 

Please provide a 5 DVC voltage through Micro USB Port to 

 

Z-Wave Network operation
 

Auto  inclusion:

  (add  using  Network  Wide  Inclusion)

primary  controller  in  inclusion  mode  then  p
once.The LED pointer will flash red up to 30 seconds while it waits 
to be included. When successfully included it will turn on a green 
surround light for 1 second. 

 

Manual  inclusion:

(add  using  Network  Wide  Inclusion) 

primary  controller  in  inclusion  mode
vertical,  point  the  LED  pointer  to  area  A  (shown  in  Fig.  1)  and 
press the Button three times within 1.5 seconds. 
will flash red up to 30 seconds while it waits to be included. When 
successfully  included  it  will  tu
second. 
 

Exclusion:

(remove) Set the primary controller in exclusion mode. 

With  the  wall  controller  vertical,  p
then  press  the  Button  three  times  within  1.5  seconds.
pointer will flash red once. When successfully excluded it 
a  30  seconds  auto  inclusion  mode
red. 
 

Reset  to  default:

With the wall controller vertical, point the 

pointer  to  area  A  then  press  the 
seconds  and  hold  at  fourth.  The  red  LED 
seconds,  release  the  button  within  2  seconds  while the  LED  goes 
out. The LED will flash for 1 second if reset succeed
flash once if not succeeded. 

Note:

  Use  this  procedure  only  in  the  event  that  the  primary 

Wave Network operation 

using  Network  Wide  Inclusion)Set  the 

primary  controller  in  inclusion  mode  then  press  the  Button 

The LED pointer will flash red up to 30 seconds while it waits 

to be included. When successfully included it will turn on a green 

using  Network  Wide  Inclusion)  Set  the 

primary  controller  in  inclusion  mode.  With  the  wall  controller 

pointer  to  area  A  (shown  in  Fig.  1)  and 

three times within 1.5 seconds. The LED pointer 

will flash red up to 30 seconds while it waits to be included. When 

rn  on  a  green  surround  light  for  1 

Set the primary controller in exclusion mode. 

With  the  wall  controller  vertical,  point  the  LED  pointer  to  area  A, 

utton  three  times  within  1.5  seconds.  The  LED 

pointer will flash red once. When successfully excluded it will enter 
a  30  seconds  auto  inclusion  mode  and  the  LED  pointer  will  flash 

With the wall controller vertical, point the LED 

pointer  to  area  A  then  press  the  Button  four  times  within  2 
seconds  and  hold  at  fourth.  The  red  LED  pointer  will  light  for  5 
seconds,  release  the  button  within  2  seconds  while the  LED  goes 
out. The LED will flash for 1 second if reset succeeded, or LED will 

Use  this  procedure  only  in  the  event  that  the  primary 

Содержание AACPH-RC1-EU

Страница 1: ...own in Fig 1 and press the Button three times within 1 5 seconds will flash red up to 30 seconds while it waits to be included When successfully included it will tu second Exclusion remove Set the primary controller in exclusion mode With the wall controller vertical p then press the Button three times within 1 5 seconds pointer will flash red once When successfully excluded it a 30 seconds auto i...

Страница 2: ...s rotated to association group 2 The value is sent after a small delay to be sure that the user has stopped rotating the device Button The Button will work regardless if the wall controlled is vertical or not It can therefore be used as a portable controller also When pressed in will send a Central Scene command to associations in group 1 according to the list below Action Command Central Scene V3...

Страница 3: ...3 ...

Страница 4: ... the network and stay awake for 10 seconds to receive commands The wake up interval minimum setting is 30 minutes and maximum setting is 120 hours And the interval step is 30 minutes If the user want to wake up the device immediately please rotate to area A and press the But ton once The device will wake up for 10 seconds every single time Configuration NO Name Size Byte Def Valid Values Descripti...

Страница 5: ...COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_CONFIGURATION Specification Operating Voltage 3 7 V Lithium Polymer Battery Low Battery Voltage 3 6 V Battery Charge Voltage 5 Vdc Micro USB Port RF Range Minimum 40 m in door 100m outdoor line of sight Operating Temperature 10 C 45 C Frequency Range AACPH RC1 EU EU 868 40MHz 69 85MHz EU AACPH RC1 US...

Страница 6: ...cordance with the in structions may cause harmful interference toradio communica tions However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or tele vision reception whichcan be determined by turning the equip ment off and on the user is encouraged to try to correct the inter ference by one of the foll...

Отзывы: