7-13
FlexiBowl - models 350 - 500 - 650 - 800
CHAPTER 7 - Maintenance
7.3.2
Replacing the solenoid valve
REPLACING THE SOLENOID VALVE
Operator qualification
Mechanical maintenance technician
PPE required
Tools to be used
Allen key
CAUTiOn!
Disconnect the power supply before taking the cover off.
Proceed as follows to
replace the solenoid valve
:
Step
Action
Picture
1
Unplug the power cable from the control panel.
A
2
Take the cover off the FlexiBowl
®
.
3
Remove the solenoid valve power cable.
4
Unscrew the 2 fixing screws
(A)
.
note:
keep the screws removed for its reassembly.
5
Remove the solenoid valve and replace it with one
with the same characteristics.