Service & Maintenance
Once a month: Press the test button
to trigger the detector. Note, putting
the alarm panel in programming mode,
will prevent the alarm sirens from
triggering as well.
Every 6 months: Vacuum or blow
dust out of the detector to help reduce
false alarms.
500mm
500mm
SL
O
PED RO
OF
Min.
200mm
Operation & Testing
During Normal Operation the LED flashes
every 45 seconds.
Pressing the Test Button will activate test
mode, triggering both the Relay and the
Buzzer.
The smoke alarm will automatically reset
when all the smoke has cleared.
Hush feature. Whilst the smoke detector is
in activated, pressing the test button for 1
second, will silence that smoke detectors
sounder.
This will not hush the controllers
sounders or other smoke detectors connected
ARROWHEAD ALARM PRODUCTS Ltd.
344b Rosedale Rd,
Albany,
Auckland.
Ph. 09 414 0085
Fax. 09 414 0088
v2.01
HM-SMOKE
AUTO RESETTING SMOKE DETECTOR
With Power Monitoring
Specifications
Detection Type
Photoelectric Chamber
Power Source
9-16 Volts DC
Standby Current
25mA
Alarm Current
20mA
Buzzer Output
85db @ 3 meters
Output Relay
N/O and N/C Contacts
100mA max
Dimensions
Ø
100mm x 55mm
Standards: GB4715-2005, EN14604, UL217
Suggested Mounting Locations
Smoke alarms must be located in escape routes on
all levels within the household unit.
On levels containing sleeping spaces, they must be
installed within the sleeping space, or within
3 metres of every sleeping space door. And they
must be audible through closed doors.
Always Refer to NZS 4514:2009 or the latest
standard for full installation recommendations.
= MOUNTING AREA
= DON’T FIT AREA
(DEAD AIR SPACE)
M
ax
. 3
0
0
m
m
CEILING
W
AL
L
BEST
LOCATION
ACCEPTABLE
LOCATION
Note. Smoke Detectors should be
mounted a minimum of 400mm away
from Air Con. or forced air vents.
Test at least once a month.
Min.
100mm
Min.
200mm
900mm
or less
Beams, joists and
exposed rafters
deeper than
460mm are
treated as walls
Min.
200mm
Always Refer to NZS 4514:2009 or the latest
standard for full installation recommendations.