Rev D
CHP Max5000 Chassis (Rear Fiber Version)
2-9
Management Signals
Local Monitoring
Craft Management Software
is used to monitor a single CHP Max5000 chassis through a direct
RS-232 connection to the CMM or SMM. The CMM or SMM sends management signals
through the SPI bus on the chassis backplane to the other modules installed in the chassis,
and status information from the modules travels back through the same route; the CMM or
SMM then communicates with the computer running the
Craft Management Software
.
Local and Remote Monitoring
The CHP Max SMM (SNMP agent) enables monitoring and management of CHP Max
equipment by communicating with an SNMP element manager with an appropriate
configuration of IP addresses and management information bases (MIBs).
Management signals enter the SMM module through the
Ethernet
SNMP port. The SMM
directs the management signals to a module in its own chassis or to another connected
chassis. The CMM module in that chassis directs the signals to the appropriate application
module. Signals from the module travel back through the SPI, to the CMM, through the daisy
chain to the SMM, which communicates with the remote management system. One SMM
may be used to permit remote management of up to an additional nine chassis with a CMM
installed in each.
Handle Kit Installation
The CHP-CHASSIS-19 and CHP-CHASSIS-19Q chassis do not have the optional front handles
installed on the chassis. An optional handle kit (P/N CHP-HANDLE-KIT) may be purchased
separately that includes two handles and four Phillips screws. This kit may only be installed
on chassis shipped after February 10, 2004. If you wish to install the front handles to the
chassis, they must be installed before the chassis is installed into the rack. Do not install
front handles to the chassis if you plan to mount a 2RU tablet PC bracket assembly (P/N
CHP-HANDLE-KIT) to the chassis.
➤
To install the handle kit (P/N CHP-HANDLE-KIT)
1. Position a new handle (P/N 862551) with the longer section of the handle at the
bottom and align the two mounting holes with the smaller mounting holes on the
front flange of the chassis.
2. Install two Phillips screws (P/N 300014-0506) and tighten using a #2 Phillips
screwdriver.
3. Repeat Steps 1 and 2 to install the other handle.
Note
All CHP-CHASSIS-19 chassis shipped before February 10, 2004 do not have the
holes required to install the optional handle kit.
Note
Do not install front handles to the chassis if you plan to mount a 2RU tablet
PC bracket assembly (P/N 1500376-001) to the front of the chassis.
Содержание CHP Max5000
Страница 2: ......
Страница 12: ...x CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Страница 100: ...4 18 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Страница 120: ...5 20 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Страница 199: ...Rev D System Management Module 2 SMM 2 7 33 Figure 7 28 Add CHPMax5000 Device Window...
Страница 261: ...1508685 Rev D CHP Max Trap Information B 29...
Страница 262: ...B 30 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Страница 266: ......