15
screws
Installation
4.4 Attaching the
Integrated Capping
Shutter
To prevent stray light from falling on the film during the
interval time, the ARRI Integrated Capping Shutter covers the
film with a thin metal plate. After each exposure the metal
plate is pushed into the film gate and removed immediately
before the next exposure. The metal plate slides into the
ICS-Guide attached to the film gate. To ensure optimum
operation, the plate of the Capping Shutter must be aligned
with the ICS-Guide.
• Switch off the main camera switch and remove the
camera from the power supply.
• Open the camera door and remove the two fastening
screws
➪
photo
. Any spacers between the hinge and
the camera housing should on inside the housing.
• Attach the Integrated Capping Shutter door by its hinge
to the camera housing and tighten slightly the two screws.
• Position the Integrated Capping Shutter door so that
there is an even gap to the housing and the door can
be correctly opened and closed.
• Tighten the two screws
➪
photo
.
• Open the Integrated Capping Shutter door by approx.
30
°
and turn the door lock to the shut position.
Содержание ICS-1