At a Glance

Understanding Your Museum360

MODE

SET

UP

DOWN

: 00

LCD Screens — The Museum360 has two LCD screens to offer 

dual-scenting power. 
POWER — The unit has three power buttons. The center switch underneath 

the LCD screens turn on the unit.  The individual switches underneath the 

LCD screens power the corresponding sides of the Museum360. 
LOCK SETTINGS — If you want to lock the settings to prevent tampering, 

hold down the SET button for 20 seconds. This will prevent anyone from 

adjusting the settings on the unit. You will hear a beep that confirms the 

settings have been locked. Repeat to unlock the settings. You will need to 

unlock the unit to adjust the settings. 
FACTORY RESET — If you want to reset the unit to the factory settings, 

hold down the MODE button for 20 seconds and the unit will return to the 

original settings. 
HVAC CONNECTION — Your Museum360 is meant to be used in 

conjunction with the central air conditioning system.

The Museum360’s LCD display provides valuable information about your 

settings. Here is a quick guide on what each item means. 
WORK/PAUSE — When the unit is in WORK mode, it is emitting aroma. 

When the unit is in PAUSE mode, it is not emitting aroma.  
TIME — The number displayed on the unit should represent the current time, 

using the 24-hour clock. 
DAY OF THE WEEK — The Museum360 allows you to have different settings 

for multiple days. The day that’s shown on the display should be the current 

day. 
SCENT/WORK/PAUSE — This screen appears when adjusting the scenting 

strength. 

Setting Up Your Museum360

Now that the diffuser is powered on, you may begin adjusting the settings to 

your liking. By default, the LCD screen will depict the current time. Note the 

unit uses a 24-hour clock so 5:30pm will be shown as 17:30 

How to Adjust the Scent Intensity

Press MODE and the display will show SCENT WORK PAUSE. This is 

where you will adjust the scent intensity for EVENT 1. You can set it 

between 5% and 95% (with 5% being the lowest setting and 95% being 

the highest setting). Press SET to confirm the intensity. 
Once you have the desired scent intensity, press MODE and EVENT 2 ON 

will appear. This will allow you to set the On Time for the second and 

remaining EVENTS. If you only have one EVENT, then press MODE until 

you reach the end of the event settings. 

1

2

Unbox your diffuser to reveal your new Museum360. Familiarize yourself with 

the parts and accessories. 
Connect the 10A-125V power cord to the diffuser and plug it into a regular 

110v outlet. Press the center button to power the unit on. Press the switch 

underneath the LCD screen to power on the individual sides. Turn both sides 

on if you are using the Museum360 as a Double. 

1

2

Setting the Operating Hours

Now it’s time to set your scenting events. The Museum360 allows up to five 

individual events to scent at different times throughout the days of the week.

To set the start time of an operating period: Press MODE. EVENT 1 ON will 

appear. This represents the On Time for the first working period. Set time as 

instructed above. 
To set the operating days: Press UP or DOWN. The days of the week will 

begin to flash. Select the days you wish to apply the working hours to. Once 

the desired days have been selected, press SET to confirm. 
To set the end time of the operating period: Press MODE. EVENT 1 OFF will 

appear. This represents the Off Time for the first operating period. Press UP 

or DOWN to adjust the hour, press SET to confirm. Repeat to set the 

minutes.  
Repeat these steps to set Events 2-5, if need be. 

Ensure there are no conflicting settings.
The unit cannot be set to run past midnight. You must split the setting 

between two different working periods. For example:
i. EVENT 1 ON —  22:00 EVENT 1 OFF  — 23:59 
ii. EVENT 2 ON —  00:01 EVENT 2 OFF —  04:00

1

2

3

4

Installing your Museum360

Ensure that your diffuser is powered off and unplugged. Affix the provided 

wall plate and atomizer as close to the ductwork as possible. Unscrew the 

bottle from the wall plate and atomizer. Pour in your Aroma360 fragrance oil 

and tightly screw the bottle back into place. 
Insert one end of the thin white tube into the hole on the back of the diffuser 

on the side you have set and are prepared to use.  Insert the other end into 

the top of the atomizer. Cut away any excess tubing. 
Just after your HVAC filter, use a screwdriver or a drill to make a small hole 

(or two if you are installing a Double Museum360) in the ductwork. These 

scent points should be the same diameter as the thick transparent tube. 
Insert one end of the thick tube about 6” into the scent hole and the other 

end into the larger hole at the top of the atomizer. Cut away any excess 

tubing and seal the scent point (see below) with HVAC tape. Ensure your 

tubing is vertical and not horizontal. 
Plug in and turn on your diffuser to begin enjoying your consistent scenting 

experience. 

1

2

3

4

5

Setting the Current Time

To set the current time, press SET and the hour will flash. Press UP or DOWN 

to adjust to the current hour and press SET to confirm your choice. (If your 

screen is unresponsive, press and hold the SET button for 20 seconds). 
The minutes will now be flashing. Press UP or DOWN to adjust to the current 

minute and press SET to confirm your choice. 
The day of the week will now be flashing. Press UP or DOWN to adjust to the 

current day of the week and press SET to confirm. 

1

2

3







The Museum360 Diffuser Unit
1 or 2 Empty  Aluminum Bottles
1 or 2 Atomizers with Attached 

Wall-Mountable Plate
Power Cord 
Thick Transparent Tubing 
Thin White Tubing 
Wall Mounting Brackets  
Spare Nozzle 

What’s included:

MODE

SET

UP

DOWN

-- : --