OPERATING MANUAL 

This kind of mini digital multimeter with test leads attached to its 

cover will give you years of satisfactory service. Before using your 
new instrument, please read this Operating Manual completely and 
familiarize yourself  thoroughly with all functions and connections. 

SAFETY RULES 

The meter has been designed according to IEC-61010 concerning 

electronic measuring instruments with a measurement category 
(CAT 11  500V) and Pollution degree 2. 

.&.. 

WARNING 

To avoid possible electric shock or personal injury, follow these 

guidelines: 

a. Do not use the meter if it is damaged. Before you  use the meter,

inspect the case.

b.  Inspect the test leads for damaged insulation or exposed metal.

Check the test leads for continuity. Replace damaged test leads
before you use the meter.

c.  Do not use the meter if it operates abnormally. Protection may

be impaired. When in doubt, have the meter serviced.

d. Do not operate the meter around explosive gas, vapor, or dust.
e. Do not measure more than the rated voltage which is marked on

the meter. 

f. Before use, verify the meter's operation by measuring a known 

voltage.

g. When measuring current, tum off circuit power before connecting 

the meter in the circuit. Remember to place the meter in series 
with the circuit. 

h. When servicing the meter, use only specified replacment parts. 
i. Use with caution when working above 30V ac rms, 42V peak, or 

60V de. Such voltages pose a shock hazard.

j. When using the probes, keep your fingers behind the finger guards 

on the probes.

k. Connect the common test lead before you connect the live test 

lead. When you disconnect test leads, disconnect the live test
lead first. 

1. Do not operate the meter with the back cover or portions of the 

case removed or loosened. 

m. To avoid false readings, which could lead to possible electric

shock or personal injury, replace the batteries as soon as the 
low battery indicator ( ·� " ) appears. 

n. This meter is designed to be indoor use.

o. CATII - Measurement Category II is for measurements

performed on circuits directly connected to low voltage
installation. ( Examples are measurements on household 
appliances,  portable tools and similar equipments. )

Do not use the meter for measurements within Measurement
Categories  Ill and IV.

Caution 

To avoid possible damage to the meter or to the equipment under 

test, follow these guidelines: 

• Disconnect circuit power and discharge all capacitors before

testing resistance, diode and continuity. 

• Use the  proper  function,  and  range  for  your  measurements.
• Before measuring current, check the meter's fuses and turn off

the power to the circuit before connecting the meter to the circuit.

• Before rotating the range switch to change functions, disconnect 

test leads from the circuit under test. 

GENERAL CHARACTERISTICS 

Display 

3 1/2 digits LCD 

Polarity indication 

Automatic negative polarity indication 

Low battery indication 

�  mark displayed on the right LCD 

Operating temperature  23±5"C  ,less than 75%RH 

Battery 

9-12V (following batteries can be 

used:23A and other equivalents)

Dimensions 

120x70x21 mm

Weight 

Approx.110g (including batteries) 

SPECIFICATIONS 

Accuracy is specified for a period of one year after calibration and 
at 23±5

°

C  with relative humidity up to 75%. 

Accuracy specifications take the form of: 

±([ % of R[number of Least Significant Digits]) 

DC VOLTAGE 

Range 

Resolution 

2V 

1mV 

20V 

10mV 

200V 

0.1V 

500V 

1V 

Max. Input voltage : 500V 

Input impedance: 1MQ 

AC VOLTAGE 

Range 

Resolutlon 

2V 

1mV 

20V 

10mV 

200V 

0.1V 

500V 

1V 

Max. Input impedance: about 500kQ 

Max. input voltage: 500V 
Frequency: 40Hz-400Hz 

Accuracy 

±(0.5%+5) 

±(0.8%+5) 

Accuracy 

Accuracy is not 

guaranteed. 

±(1.2%+10) 

Indication:  Average  respond,rms  of  sine  wave 

DC CURRENT 

Range 

Resolution 

Accuracy 

200mA 

0.1mA 

±(2%+2) 

Overload  Protection :  Fuse,  F 250mA L 250V, Fast action 

RESISTANCE 

Range 

Resolution 

Accuracy 

2k 

1 Q

20k 

10 Q 

±(1.0%+2) 

200k 

100Q 

2000k 

1kQ 

Open circut Voltage:0.4V 

Overload protection:250V DC or  rms  AC 

DIODE 

Resolution  Test Current Max. 

Open circuit Voltage 

Overload

Protection 

1mV 

0.8mA 

3.2V 

250VrmAC 

BUZZER 

It will sound when the resistance value is under 500 

DESCRIPTION OF PANEL 

@) 

1. LCD 

2.  Function  Switch

3. Range Switch
4. "black" or "red" test lead

OPERATING INSTRUCTION 

DC VOLTAGE MEASUREMENT 

Set the function switch at 

position. 

Set the range switch at desired position. If the magnitude of voltage 
is not known beforehand, set the switch at the highest range and 
reduce until satisfactory reading is obtained. 

Connect test leads to device or circuit to be measured. Voltage 
value will appear on the display along with the voltage polarity. 
When the range switch  is  in 500V position,  a "HV" sign will appear 
on the display to remind you of high voltage measuring. 
Special attention should be paid. 

=�� 

REC 

.... 0 

2lo• 

,,., 

.,.·;f. 

a . .:. 

#< 

�a»J.w(: 

BLACK 