Table 3-61 SAMPLED_STATUS Register bit assignments
Bits
Name
Function
[31:3]
-
Reserved.
[2:0]
SAMPLED_STATUS[2:0]
Indicates that PVT measurements are valid:
0b0
: Not valid.
0b1
: Valid.
Reset value
0x000
.
COUNTER_STATUS Register
The COUNTER_STATUS Register characteristics are:
Purpose
Stores the current value of the reference counter.
Usage constraints
This register is read-only.
Memory offset and full register reset value
See
3.9.1 PVT sensor control registers summary
.
The following table shows the COUNTER_STATUS Register bit assignments.
Table 3-62 COUNTER_STATUS Register bit assignments
Bits
Name
Function
[31:0]
COUNTER_STATUS
Stores the current value of the reference
counter.
Reset value
0x0000_0000
.