1.

 

OVERVIEW 

This instruction manual contains all information needed to install and maintain the ARL-BR-IS range of safety barriers. Indicated 

below are the manual’s current revision and number of pages. Please check this manual and its control drawings for missing pa

ges. 

The installation cannot continue unless all pages are present. 

Table 1: List of Controlled Documents as part of this manual. 

Document 

Description 

Number of Pages 

Document #5902 

ARL-BR-IS Series Instruction Manual 

 

Control Drawing #5210 

ARL-BR-IS General Dimensions 

Control Drawing #5211 

ARL-BR-IS Barrier Label Drawing 

Control Drawing #5213 

ARL-BR-IS Installation and Wiring Diagram 

 

Please check Section 5 for a list of safety checks that need to be done when using the ARL-BR-IS series Safety Barriers for Intrinsically 
Safe (IS) interfaces between safe and hazardous areas. This section must be consulted each time before beginning any installation of 
the barriers. 

It is assumed that all necessary system design, specification and engineering factors have been taken into account 

before

 installation 

of the barriers. Please refer to the above documentation listed to assist in pre-planning your installation. The documents consist of 
theory, design, application, specifications and certifications of the safety barrier. 

If not supplied with the product, these publications are available either from our website (

www.arlynscales.com

) or on request from 

our factory. 

2.

 

FACTORY MUTUAL APPROVAL AND INTRINSIC SAFETY 

The ARL-BR-IS Safety Barrier has been rated intrinsically safe by Factory Mutual only if the installation is performed by a qualified 

technician who conforms to the guidelines described in this manual. Consult the chapter titled “Installation and Wiring” along with 

the control drawings in the back of this document for information pertaining to the installation and wiring of the approved barrier. 

This system, when installed in accordance with this document, has been approved by Factory Mutual for use in the following 
classified areas: 
 

Associated Intrinsically Safe Apparatus providing connections for use in Class I, II, III, Division 1, Groups A, B, C, D, E, F and G; Class 
I, Zone 0, Aex ia IIC Ga; in accordance with Control Drawing No. 5213; Hazardous (Classified) Locations. Associated Nonincendive 
Apparatus providing connections for use in Class I, II, III Division 2, Groups A, B, C, D, F, and G; in accordance with Control Drawing 
No. 5213; Hazardous (Classified) Locations 

3.

 

DESCRIPTION 

3.1.

 

Introduction 

The ARL-BR-IS series set of Safety Barriers are anywhere from 1- to 5-channel devices that use intrinsically safe explosion proof 
techniques to pass electrical signals between safe and hazardous areas while limiting energy transfer to a level that cannot ignite 
flammable atmospheres. 

When the ARL-BR-IS series of safety barriers are connected in series with wiring entering any hazardous area, these barriers prevent 
explosions in all normally occurring explosive atmospheres 

 including mixtures of air with flammable gases, vapors, dusts and fibers 

- if a fault or faults develop in the safe area. 

3.2.

 

ARL-BR-IS Series Barriers 

The series is based on the most common uses in dealing with a very specific set of entity parameters. They are primarily designed to 

work with Arlyn’s MKE

-5-IS(-C) Intrinsically Safe Weighing System 

and Arlyn’s Intrinsically Safe load cells. However, these 

barriers are 

Содержание ARL-BR-IS Series

Страница 1: ...ARL BR IS Series Safety Barriers User Manual 59 Second Street East Rockaway NY 11518 800 645 4301 www arlynscales com Doc 5902 Revision 1 1 ...

Страница 2: ...ers 3 4 SAFETY CHECKS 4 5 WIRING CONNECTIONS 4 5 1 Overview 4 5 2 Signal Connections 4 5 2 1 Precautions 4 5 2 2 Wiring 5 5 2 3 Power Supply Connections Grounding and General Considerations 5 6 ENTITY PARAMETERS RATINGS 6 7 MAINTENANCE 6 7 1 General Considerations 6 7 2 Routine Inspection 6 8 LIMITED WARRANTY 7 9 CONTROL DRAWINGS 7 ...

Страница 3: ...lation is performed by a qualified technician who conforms to the guidelines described in this manual Consult the chapter titled Installation and Wiring along with the control drawings in the back of this document for information pertaining to the installation and wiring of the approved barrier This system when installed in accordance with this document has been approved by Factory Mutual for use ...

Страница 4: ...nals 5 Make sure all hazardous area cables are well secured and are segregated from all other cables 6 Make sure all hazardous area cable parameters for hazardous area circuits are not exceeded see relevant control drawings 7 Make sure all hazardous area cables and cable screens are terminated correctly the latter preferably via the earth ground lug on the hazardous side of each barrier 8 Make sur...

Страница 5: ... 4 Connect the wires as designated below depending on your barrier model type Table 3 Wiring Map MODEL SIGNAL EXAMPLES SAFE AREA HAZARDOUS AREA Terminal Block Pin Terminal Block Pin ARL BR IS PWR 5VDC Line or less PWR 485 P 1 PWR P 9 GND PWR 485 P 2 PWR P 10 ARL BR IS LC LC Excitation E or RS422 A Loadcell LC E 5 LC EXC E 13 LC Excitation E or RS422 B Loadcell LC E 6 LC EXC E 14 LC Signal S or RS4...

Страница 6: ...lating to the safety of plant and personnel Care must be taken to prevent any inadvertent direct connection between hazardous and safe area circuits and at all times the safety precautions discussed in section 5 MUST be observed Check that a Barriers are of the types and polarities specified in the safety documentation b The barriers are attached securely and correctly Earth Ground to make sure th...

Страница 7: ...ent misuse neglect alteration improper installation improper repair or improper testing Arlyn Scales will be the sole judge of all alleged non conformities Such equipment has not been modified altered or changed by any person other than Arlyn Scales Arlyn Scales will have reasonable time to repair or replace the defective equipment The buyer is responsible for shipping both ways In no event will A...

Страница 8: ... OF CIRCUITS AND SYSTEMS INC DBA ARLYN SCALES ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CIRCUITS AND SYSTEMS INC DBA ARLYN SCALES IS PROHIBITED 1 00 DIEGO 10 4 2019 MMK 10 4 2019 CIRCUITS AND SYSTEMS INC 59 2ND STREET EAST ROCKAWAY NY 11518 COPYRIGHT c 2019 ALL RIGHTS RESERVED TITLE ARL BR IS GENERAL HOUSING DIMENSIONS THIS IS A FACTORY MUTUAL CONTROLLED DOCUMENT NO ...

Страница 9: ... NOT BE USED WITHOUT WRITTEN PERMISSION COPYRIGHT 2019 ALL RIGHTS RESERVED DRAWN MMK TITLE ARL BR IS HOUSING LABEL DRAWING CHECKED MMK DRG NO DOC 5211 PAGE 1 of 2 THIS IS A FACTORY MUTUAL DOCUMENT NO MODIFICATIONS OR REVISIONS ARE ALLOWED WITHOUT PRIOR APPROVAL FROM FACTORY MUTUAL REV 1 00 Location of Entity Label Text Location of Approval Label Text Location of Model Label Text ARL BR IS XX YY FR...

Страница 10: ...OULD NOT BE USED WITHOUT WRITTEN PERMISSION COPYRIGHT 2019 ALL RIGHTS RESERVED DRAWN MMK TITLE ARL BR IS HOUSING LABEL DRAWING CHECKED MMK DRG NO DOC 5211 PAGE 2 of 2 THIS IS A FACTORY MUTUAL DOCUMENT NO MODIFICATIONS OR REVISIONS ARE ALLOWED WITHOUT PRIOR APPROVAL FROM FACTORY MUTUAL REV 1 00 TOP VIEW BOTTOM VIEW ...

Страница 11: ...lowing is true Vmax or Ui Voc Vt or Uo Imax or Ii Isc It or Io Combined Isc It or Io for ALL BARRIERS Imax Po Pi Ca or Co Ci Ccable La or Lo Li Lcable HAZARDOUS AREA APPROVALS This system when installed in accordance with this document has been approved by Factory Mutual for use in the following classified areas Associated intrinsically safe apparatus providing connections for Class I II III Divis...

Страница 12: ...RS INSTALLATION AND WIRING DIAGRAM CHECKED MMK DRG NO DOC 5213 SHEET 2 of 4 THIS IS A FACTORY MUTUAL DOCUMENT NO MODIFICATIONS OR REVISIONS ARE ALLOWED WITHOUT PRIOR APPROVAL FROM FACTORY MUTUAL REV 1 00 Model ARL BR IS RS 2 Channel Barrier Total Entity Parameters V 5 715V oc I 36mA sc P 40mW o C 46uF a L 27 4mH a Model ARL BR IS PWR RS 3 Channel Barrier Total Entity Parameters V 6 135V oc I 1 736...

Страница 13: ...C 5213 THIS IS A FACTORY MUTUAL DOCUMENT NO MODIFICATIONS OR REVISIONS ARE ALLOWED WITHOUT PRIOR APPROVAL FROM FACTORY MUTUAL REV E E S S 13 14 15 16 5 6 7 8 ARL BR IS LC INTRINSICALLY SAFE BARRIER J5 J6 J2 13 14 15 16 5 6 7 8 ARL BR IS LC INTRINSICALLY SAFE BARRIER J5 J6 J2 1 00 Model ARL BR IS LC 4 Channel Barrier Total Entity Parameters V 5 715V oc I 72mA sc P 80mW o C 46uF a L 6 8mH a HAZARDOU...

Страница 14: ...RIOR APPROVAL FROM FACTORY MUTUAL REV 1 00 Model ARL BR IS PWR LC 5 Channel Barrier Total Entity Parameters V 6 135V oc I 1 772A sc P 850mW o C 34uF a L 11 3uH a Ch 2 10 Ground HAZARDOUS AREA UNCLASSIFIED AREA Hazardous Location Apparatus Associated or Non Hazardous Location Apparatus e GROUNDING ALL SHEETS The ARL BR Series barriers must be grounded using the Ground Lug provided on the unit The g...

Отзывы: