Aritech ATS1201 Скачать руководство пользователя страница 1

M

ODEL 

ATS1201 

 

 

English Data-interface 

M

OUNTING THE UNIT 

 

Mount the unit via screws or bolts through the four mounting holes in the base. 
Ensure the unit is mounted on a flat, solid, vertical surface such that the base 
will not flex or warp when the mounting screws/bolts are tightened. 

C

ONNECTING THE DATA GATHERING PANEL TO A CONTROL PANEL 

 

Refer to the control panel installation guide for instructions. 

C

ONNECTIONS

: 5

MM PLUG ON SCREW TERMINALS 

(

FIGURE 

Power 

Connection of the 23 Vac, AC from the transformer. 

Earth 

Earth wires from all pieces of equipment must be earthed at 
one system earth. For further detail see the ATS control panel 
installation guide. 

Note 

Power and battery wires should be firmly tied in order to avoid 
short circuits to any other part of the system in case a 
connection of the wire is broken. 

Batt 

+ - connections to a 12V/6.5AH maximum sealed lead acid 
battery. 

AUX PWR

 

12Vdc auxiliary power output to supply detector, etc. 700mA 
maximum current. 

J2 

DATABUS

 

Data +, Data - and common 0V connection to the system 
databus. Remote units can be up to 1.5 km from the control 
panel. Also see the control panel installation guide. 

J2 

TAMPER

 

Connection for panel tamper switches. Can only be used with 
normally closed contacts such as the panel tamper switches.

 

Normally closed front panel tamper contact 

 

Normally closed rear panel tamper contact 

J4 J6 J7 

 

 

Zones 1 to 8 require 4k7 end-of-line resistors for normal state.

J7 – 

SIREN

 

Positive and negative connection to external 8 Ohm siren 
speaker. 1k resistor must be fitted across these terminals if 
the siren is not connected. The siren output is the 16th (last) 
output allocated to the DGP address. e.g. on DGP 1 the siren 
is output 32. On DGP 2 the siren is output 48, etc. 

 

LED’

S

 

RX   

LED flashes to indicate polling data is being received on the 
system databus from the ATS control panel. If the LED does 
not flash the control panel is not operational or the databus is 
faulty (usually cabling). 

TX 

LED flashes to indicate the DGP is replying to polling from the 
ATS control panel; If the RX LED flashes but the TX LED 
does not, it indicates that the DGP) is nor programmed to be 
polled in the control panel or is not addressed correctly. 

 

Z

ONE AND OUTPUT NUMBERING

 

Control panel 

 

1  –  16 

DGP8 

 129  - 144 

DGP1 

 17 - 32 

DGP9 

 145 - 

160 

DGP2 

 33 - 48 

DGP10 

 161 - 

176 

DGP3 

 49 - 64 

DGP11 

 177 - 

192 

DGP4 

 65 - 80 

DGP12 

 193 - 

208 

DGP5 

 81 - 96 

DGP13 

 209 - 

224 

DGP6 

 97 - 

112 

DGP14 

 225 - 

240 

DGP7 

 113  - 128 

DGP15 

 241  - 256 

O

UTPUT NUMBERING

 

A DGP can have a maximum of 16 outputs available as relays or open 
collectors outputs. The output numbers are the same as the 16 zone numbers 
allocated to the DGP address. 

Z

ONE NUMBERING

 

The ATS 1201 has 8 zones that can be expanded using the ATS 1202 (8 
zones) to a maximum of 32 zones. If the number of zones exceeds 16, then the 
zones are taken from the next DGP address and DGP ceases to exist. 
e.g. DGP 1 has 24 zones (zones 17 to 40). The next DGP in the system must 
now be addressed and polled as DGP 3, because zones 33 to 40 on DGP 1 
have taken from DGP 2. 
The unused zone numbers in the system (zones 41 to 48) must be 
programmed in the zone database as Type 0. 

C

ONNECTIONS

HEADERS AND SOCKETS

 

J5 –  
E

XT I

/

PS

 

Connection to ATS1202 8-zone expansion cards via 10-way 
cable supplied with the expander card. Set dipswitch A of the 
DGP to ON if two or three expansion cards are connected. 
Dipswitches 1 to 3 on the expansion card are used to identify 
the expander number. See the ATS1202 installation guide for 
details. 

J8  
-

OUTPUTS

 

+12Vdc supply and open collector or data output for 
connection to ATS 1810, ATS 1811 and ATS 1820 output 
cards via 10-way cable supplied with the output card. Up to 
sixteen outputs are available with 8-way relay or 16-way open 
collector cards, (4-way and 8/16-way output cards cannot be 
used together on the same DGP). 

 

L

INKS

 

T

ERM

 

Refer to the control panel installation guide. 

TST

 3  

Disable mains fail monitoring.  

E

ARTH

,  +12V 

 

 

DGP 

DIPSWITCH SETTINGS

 

1 - 4  Address setting. Set switches 1 - 4 to OFF to disable the DGP. See 

also figure for correct address settings. 

ON - DGP has 2 or 3 ATS1202 zone expanders connected to J5. 
OFF - DGP has none or only 1 ATS1202 connected to J5. 

ON - ATS1811 8-way relay card or ATS1820 16-way open collector 
card connected to J8. 
OFF - no ATS1811 or ATS1820 connected to J8. Use this setting also 
if an ATS1810 is connected to J8.  

CD 

OFF – Not used. 

O

VER

-

CURRENT PROTECTION

 

F1 

1 A fuse to limit “Aux” O/P current. (

AUX PWR

 and 

SIREN

).  

F2 

3 A fuse to limit current when unit is running on the battery.  

C

ONNECTING THE MAINS POWER

 

Use the mains connector terminal for connecting the mains power supply. A 
fixed or flexible mains lead to an earthed mains outlet can be used. 
 

IMPORTANT: Disconnect the mains power before opening the cabinet! 

 

 

 

105066  