background image

 ATS1100/1105

 

1 2 3 4 

SW2

1 2 3 4 

B

SW1 Dip Switch

 

Rx 

SD

SD 

SD 

SD

ON

ON

ON 

ON 

Tx

1

 

2

 

3

 

4

 

1

 

2

 

3

 

4

 

1

 

2

 

3

 

1

 

2

 

3

 

4

 

4

 

J2 

RAS 1 

RAS 2 

RAS 3 

RAS 4 

SD

SD 

SD 

SD

ON

ON

ON 

ON 

A

T

S

30

00

/4

00

0 (

J1

0)

 

+

12

  0

V

   D

+

   

D

-  

IN

 O

U

T

 

1

 

2

 

3

 

4

 

1

 

2

 

3

 

4

 

1

 

2

 

3

 

4

 

1

 

2

 

3

 

4

 

RAS 5 

RAS 6 

RAS 7 

RAS 8 

J3 

SD

SD 

SD 

SD

ON

ON

ON 

ON 

 

 

1

 

2

 

3

 

4

 

1

 

2

 

3

 

4

 

1

 

2

 

3

 

4

 

1

 

2

 

3

 

4

 

RAS 9 

RAS 10 

RAS 11 

RAS 12 

SD

SD 

SD 

SD

ON

ON

ON 

ON 

1

 

2

 

3

 

4

 

1

 

2

 

3

 

4

 

1

 

2

 

3

 

4

 

1

 

2

 

3

 

4

 

RAS 13 

RAS 14 

RAS 15 

RAS 16 

 

English 

8-Area LCD RAS

M

OUNTING THE UNIT

 

Attach the mounting box using screws. Secure the PCB with the screw 
supllied. Secure the keypad cover with the screw supplied. 
When a pry-off tamper is required, use a screw in the back of the keypad 
(see figure A, 

).  

C

ONNECTING THE KEYPAD TO A CONTROL PANEL 

(

FIGURE 

A)

 

 Refer to the control panel installation guide for instructions. 

LED

(

SEE FIGURE 

A) 

RX 

LED flashes to indicate polling data is being received on the system 
databus from the ATS control panel. If the LED does not flash the 
control panel is not operational or the databus is faulty (usually 
cabling). 

TX 

LED flashes to indicate the arming station (RAS) is replying to polling 
from the ATS control panel. If the RX (Rx0) LED flashes but the TX 
(Tx0) LED does not, the arming station (RAS) is not programmed to 
be polled in the control panel or is addressed incorrectly. 

LED I

NDICATIONS ON KEYPAD

 

Area 

8 red LED’s illuminate when area 1-8 (or 9-16) are armed. 
Will blink (armed) or flash (disarmed) on alarm. 

Mains 

Green LED illuminates if 230 VAC mains power is available. 

Alarm 

Red LED illuminates on any alarm in an area assigned to the 
keypad. 

Fault 

Yellow LED illuminates on fault’s in the system. 

C

OMMS CONNECTIONS 

(

FIGURE 

A, 

TERMINAL 

J3) 

 

+12 

0V

 

Power supply. If the distance between the arming station and the 
control panel does not exceed 100m, then the arming station can be 
powered using the Comms + and – from the control panel. Otherwise 
use AUX PWR from DGP’s or an auxiliary power supply.  

D+ 

Data positive and data negative connection of the databus. 

D - 

Remote units can be up to 1.5 km from the ATS control panel. 

IN 

A request to exit button (normally open, momentary push-button 
switch) can be connected across “IN” and “-“. When pressed, this 
button controls the request to exit function. 

OUT  Open collector output, 50 mA maximum. It is the first output of 

the output control group that is assigned to this arming station. 

RAS 

DIP SWITCH SETTINGS 

(

FIGURE 

A) 

 SW1 dip switches  

These are used to identify the RAS address. See figure B for settings. 

 SW2 “A, B, C, Term” 

These are used to terminate the databus and enable various other 
functions, as described below: 

SW2-1, A Area 9-16 

OFF  The 8-area LEDs display the status of areas 1 to 8. 
ON 

The 8-area LEDs display the status of areas 9 to 16. 

SW2-2, B Keypad backlight 

OFF  The keyboard backlight times out. 
ON 

The keyboard backlight stays on continuously. 

SW2-3, C Magnetic card format  (ATS1105 only) 

OFF ATS 

format 

ON Non-ATS 

formats. 

 

(e.g., credit cards, any cards with data on track 2). 

SW2-4, TERM 

OFF  Not the last device on the databus. 
ON 

Terminates the databus if this RAS is the last device on the 
databus. See also the ATS control panel’s installation guide. 

R

EADERS 

C

ONNECTIONS 

(ATS1105 

ONLY

)

 

(

FIGURE 

A, J2) 

+5 VDC supply and data connections for ATS magnetic card readers 
(ATS1105 only). 

D1/D Read data pulse / Wiegand D1 line 

D0/C Read clock pulse / Wiegand D0 line 

3 GND 

(0V) 

4 +5 

VDC 

5 +12 

VDC 

 

Additional functionality. 

Adjust LCD contrast 

 

By pressing the clear button at the same time with the arrow up or 

 

arrow down key.

 

 

 

 

 

 

105066  

г

Москва

ул

Спартаковская

д

.11, 

корп

. 1,  

тел

. (095) 787-33-42, (095) 937-90-57; 

факс

 (095) 937-90-55 

 

Содержание ATS1100

Страница 1: ...he distance between the arming station and the control panel does not exceed 100m then the arming station can be powered using the Comms and from the control panel Otherwise use AUX PWR from DGP s or an auxiliary power supply D Data positive and data negative connection of the databus D Remote units can be up to 1 5 km from the ATS control panel IN A request to exit button normally open momentary ...

Страница 2: ...нный узел может быть расположен на удалении до 1 5 км от контрольной панели ATS IN Кнопка запроса выхода нормально разомкнутая кнопка кратковременно замыкает контакты может быть установлена между контактами IN и При нажатии кнопка управляет функцией запроса выхода OUT Выход открытый коллектор максимум 50 мА Это первый выход контроллера выходов который назначен данному ППС УСТАНОВКА МИКРОПЕРЕКЛЮЧАТ...

Страница 3: ...DC Current consumption Потребляемый ток max 185mA Dimensions W x H x D Размеры В x Ш x Г 168mm x 126mm x 40mm Operating temperature Рабочая температура 0 C 50 C Humidity Non condensing Влажность без конденсации 95 3 105066 г Москва ул Спартаковская д 11 корп 1 тел 095 787 33 42 095 937 90 57 факс 095 937 90 55 ...

Отзывы: