15
B063
Removing the overheat thermostat
1. Disconnect the overheat thermostat electrical
connections “N1” (F
IG
. 1.54);
2. Then remove the thermostat from its mounting by
releasing the securing clip (F
IG
. 1.55).
Removing the heating temperature sensor (N.T.C.)
1. Pull off the electrical connector “P1” and unscrew the
sensor probe using a suitable spanner (F
IG
. 1.56).
F
IG
. 1.54
F
IG
. 1.55
Removing the D.H.W. temperature sensor (N.T.C.)
1. Pull off the electrical connector “Q1” and unscrew the
sensor probe using a suitable spanner (F
IG
. 1.57).
F
IG
. 1.57
Removing the divertor valve actuator
1. Unplug the electrical connector “R1” (F
IG
. 1.58);
2. Release the retaining clip “S1” and remove the divertor
valve actuator.
F
IG
. 1.58
Removing the D.H.W. flow switch
1. Unplug the electrical connector “T1” (F
IG
. 1.59);
2. Release the retaining clip “V1” and remove the D.H.W.
flow switch.
F
IG
. 1.59
N1
P1
Q1
S1
R1
F
IG
. 1.56
T1
V1
80.eps
83.eps
87.eps
60.eps
74.eps
30.eps