CE Certification
Heat Input
max/min kW
25.6/11.0
Heat Output
max/min kW
23.1/9.2
Efficiency of Nominal Heat Input
%
90.2
Efficiency at 30% of Nominal Heat Input
%
87.8
Heat Loss to the Casing (³T=50°C)
%
1.2
Flue Heat Loss with Burner Operating
%
8.6
Flue Heat Loss with Burner Off
%
0.4
Maximum Discharge of Fumes (G20-G25) Kg/h
59
Residual Discharge Head
mbar
1.15
Consumption at Nominal Capacity (G20-G25) m
3
/h
2.72/3.32
Gas Consumption after 10 Minutes*
m
3
0.32/0.39
(15°C, 1013 mbar) (G30-G31)
Kg/h
2.02/2.00
Temp. of exhaust fumes at nominal
capacity (G20-G25)
°C
137
CO
2
Content
%
5.8
O
2
Content
%
9.2
CO Content
ppm
32
Minimum Ambient Temperature
°C
+5
Head Loss on Water Side (max) (³T=20°C) mbar
200
Residual Head of System
bar
0.25
Heating Temperature
max/min °C
82/42
Domestic Hot Water Temperature
max/min °C
56/36
D.H.W. Flow Rate ³T=35°C
l/min
9.5
D.H.W. Flow Rate ³T=35°C
gal/min
2.1
D.H.W. Minimum Flow Rate
l/min
2.6
Pressure of Domestic Hot Water
max/min bar
6/0.2
Expansion Vessel Capacity
l
7
Expansion Vessel Pre-load Pressure
bar
1
Maximum Water Content in System
l
145
Maximum Heating Pressure
bar
3
Nominal Pressure Natural Gas (G20-G25) mbar
20-25
LPG (G30-G31) mbar
30-37
Electrical Supply
V/Hz
230 / 50
Power Consumption
W
150
Protection Grade of Electrical System
IP
44
Internal Fuse Rating
FAST 2 AT
Weight
Kg.
47
G.C. Number
47-116-10
4
B023
1.2
Technical Information
chamber visually.
4 - Visual check of the combustion: clean burners if necessary.
5 - With reference to point 3, dismantle and clean the combustion chamber if
necessary.
6 - With reference to point 4, dismantle and clean the injectors if necessary.
7 - Visual check of the primary heat exchanger:
- check for overheating of the exchangers fins;
- clean the exhaust side of the exchanger and fan if necessary.
8 - Regulate the gas pressure, ignition pressure, partial flame, maximum
flame.
9 - Check proper operation of the heating safety system:
- maximum safety temperature;
- maximum safety pressure.
10 - Check the proper operation of the gas safety system:
- gas or flame safety device;
- gas valve safety device.
11 - Check that the electrical connections have been made in compliance with
the instructions shown in the installation instructions.
12 - Check the efficiency of the hot water supply (flow and temperature).
13 - Check general operation of the appliance.
14 - Check the exhaust system for the combustion products.
29.8/12.0
27.3/10.1
91.6
88.3
1.3
7.1
0.4
62
1.4
3.16/3.86
0.37/0.45
2.35/2.32
128
6.6
8.0
34
+5
200
0.25
82/42
56/36
11.2
2.5
2.6
6/0.2
7
1
145
3
20-25
30-37
230 / 50
190
44
FAST 2 AT
47
47-116-12
A/23 MFFI
A/27 MFFI
*Calculated at 70% maximum output
Содержание EURO COMBI 47-116-10
Страница 16: ...16 B023 A 23 MFFI A 27 MFFI EX C MI FFI 8 A 23 MFFI A 27 MFFI...
Страница 25: ...NOTES 25 B023...
Страница 26: ...26 B023 NOTES...
Страница 27: ...27 B023...