276
-22-
Pressing the “Prog” key displays the programmed
switching times until the first free memory location
appears in the display “-- : --”.
If you now press the “Prog” key once again, the
number of free memory locations will be displayed,
e.g. “
Fr 20
”. If all memory locations are occupied, the
display “
Fr 00
” appears.
C
HANGING THE PROGRAMMED SWITCHING TIMES
Press the “Prog” key repeatedly until the switching time you want to change is
displayed. You can now enter the new data. See “E
NTERING THE SWITCHING TIMES
”.
N
OTES ON STORING SWITCHING TIMES
:
If you end your entry of the switching times by pressing the “Prog” key, the
switching time you have entered will be stored and the next memory location
displayed.
Entry of further switching times is also carried out as described in “E
NTERING THE
SWITCHING TIMES
”.
In addition, a complete switching command is stored automatically after around
90 seconds provided no other key is pressed.
The time switch then enters the automatic operating mode and displays the
current time again.