Rapid

Rapide

Rapido

Scaldacqua Elettrico Rapido
Rapid
 electric water heater
Chauffe-eau Electrique Rapide
Elektrischer Wasserdurchlauferhitzer

025.0.60.055.1.05

Realizzazione grafica : 

Andreani - Foligno  -   Stampa:

 Litog

raf s

.r

.l.

 - Jesi

Merloni TermoSanitari  SpA

Viale Aristide Merloni, 45
60044 Fabriano (AN)
Tel. 0732.6011
Telefax. 0732.602331
Telex 560160
http://www.mts.it

Содержание BOOSTER

Страница 1: ...uffe eau Electrique Rapide Elektrischer Wasserdurchlauferhitzer 025 0 60 055 1 05 Realizzazione grafica Andreani Foligno Stampa Litograf s r l Jesi Merloni TermoSanitari SpA Viale Aristide Merloni 45 60044 Fabriano AN Tel 0732 6011 Telefax 0732 602331 Telex 560160 http www mts it ...

Страница 2: ...rage water heaters e are convinced that BOOSTER will fully satisfy your needs because it is the fruit of our experience in top quality and technology which ensures that all ARISTON products measure up to the confidence placed in them by families all over the world BOOSTER has been designed for the person who just like you demands maximum performance W We recommend reading this handbook carefully i...

Страница 3: ...w to fasten the wall 5 2 Plumbing 5 3 Wiring 25 5 4 Useful information 6 USE 25 7 DESCRIPTION OF THE CONTROLS 26 8 MAINTENANCE 26 8 1 How to remove the cover 27 8 2 How to remove the flange 8 3 Regular maintenance 28 8 3 1 How to remove deposits from the heating elements 8 3 2 Water safety device 29 8 4 Special maintenance 8 4 1 Replacement of anode 8 4 2 How to reset the bipolar safety device 8 4...

Страница 4: ...e box in the position shown in the diagram and open it Then consult your instruction handbook Remove box I Take out the cardboard tubes T Remove the protective bag and throw it away Hold the box on both sides and carefully turn it upside down The water heater must be left on its polystyrene base B until it is ready to be installed HOW TO REMOVE THE PACKAGING ...

Страница 5: ... connections at the bottom Control panel 1 2 G cold water inlet 1 2 G hot water outlet Cover Rating plate DESCRIPTION OF THE SYSTEM 2 BO0299 010 Safety valve SC1406 202 Parts to fasten the water heater support SEM0510 120 Sector 5 6 7 2 1 ACCESSORIES SUPPLIED WITH THE HEATER Adjustment knob ...

Страница 6: ...ty of current The upper heating element 2 enables only a limited amount of water H to be heated This system gives you a smaller amount of hot water about 20 30 of the total capacity in a shorter time thus reducing consumption Use the BOOSTER key for this function The temperature in area H is preset to the maximum thermostat temperature setting and is controlled by means of the changeover switch th...

Страница 7: ...0 1310 CAPACITY l APPLIANCE WEIGHT kg N BOOSTER HEATING TIME T 45 C h min BOOSTER power W NORMAL TOTAL HEATING TIME T 45 C h min NORMAL power W 3 2 TECHNICAL DATA 1 0 0 8 0 M O D E L BO0299 080 3 3 DIMENSIONS A 783 935 MOD 80 100 B 605 757 9 480 100 165 A B ø 450 310 100 ...

Страница 8: ...ement Changeover switch thermostat 2 C 11 C Red warning light Upper green warning light Changeover switch Lower green warning light Temperature limiting device Red warning light L N BO0299 035 1 3 2 C Operational thermostat CONNECTION DIAGRAM 10 3 2 1 1 2 C BO0299 075 NORMAL BOOSTER ...

Страница 9: ... to turn this tap A safety valve A supplied with the appliance must be screwed on to the other side of the con nection Connect the latter to the mains cold water pipe by means of a hose pipe F Also install a drain pipe C to be used if the tap B is opened When the safety valve is screwed on take care not to force it as far as it will go and do not tamper with it A slight drip is normal during heati...

Страница 10: ...USEFUL INFORMATION If after a certain period of time no hot water comes out of the taps before contacting your Technical Assistance Service make sure that the plumbing and electrical wiring is as described in the relevant paragraphs If the electricity is cut off to the lower heating element the amount of hot water available is 20 30 of the total capacity BOOSTER running You should still contact yo...

Страница 11: ...just the temperature up to a maximum temperature of 75 C When the knob is turned to E Economy water temperature is preset at about 60 C DESCRIPTION OF THE CONTROLS 7 BO0299 040 16 1 2 3 5 4 6 7 1 Upper heating element warning light on 2 Lower heating element warning light on 3 Adjustment knob 4 BOOSTER button 5 BOOSTER function warning light 6 NORMAL button 7 NORMAL function warning light Before c...

Страница 12: ... tap Remove the cover as shown previously figs 17 18 8 1 HOW TO REMOVE THE COVER In order to gain access to the electrical part remove cover E as follows unscrew screws A B C D that fasten it remove the cover by pulling it downwards as shown in the diagram 18 BO0299 090 SEM0510 280 A C B D E 17 18 19 BOO15199 F18 20 BOO15199 F19 Remove probes S S Disconnect terminals T T F ...

Страница 13: ...remove any hard water deposits that have formed on the heating elements about once every two years Remove the cover and the flange as shown in paragraphs 8 1 and 8 2 If you do not wish to use the special acids available for this type of operation you can gently crumble the deposit but take care not to damage the outer protection of the heating elements BOO150199 F11 8 3 1 HOW TO REMOVE DEPOSITS FR...

Страница 14: ...e from the electrical mains supply Remove the cover and the flange as shown in paragraphs 8 1 and 8 2 Unscrew anode 2 and replace it 27 BOO150199 F11 If the water should overheat a safety thermal switch in compliance with IEC norms interrupts the electrical circuit on both feed phases to the heating element Contact your Technical Assistance Service 8 4 2 HOW TO RESET THE BIPOLAR SAFETY DEVICE 8 4 ...

Страница 15: ...eristics described in this hand book and reserves the right to make any modifications it deems necessary without priornotice or replacement This appliance complies with the requirements set forth in EMC directive 89 336 EEC concerning the electromagnetic compatibility ...