6.1.3 Flashing (No flame detected)
Triple
Flashing
(x3)
No flame detected
Insufficient
pressure gas
Check the pressure
reducer of the installation
Insufficient
pressure gas
Check the pressure
reducer of the installation
Problem on
the safety
valve
Repalce the
gas valve gaz
Safety valve
correct
Gaz pressure
correct
Gaz pressure
correct
Check the static
pressure gaz between
17 et 25 mb natural gas
and 28 et 40 GPL
Check the dunamic
pressure gaz between
17 et 25 mb natural
gas and 28 et 40 GPL
Check the
valve gas
Check the position of
the ignition/ionisation
electrode
Replace the
batteries
Batteries OK
Check the wire and replace the
main board if necessary
Check the
battery
Batteries not OK
Repositioning the
electrode at the
right distances