65
GB
Supplier’s model identi
fi
er
ELECTRONIC
Model
12 HP CA-E
16 HP CA-E
20 HP CA-E
Certi
fi
cate CE
0694BN3853
Nominal capacity
I
120
150
200
Real capacity
I
110
160
185
Nominal pressure
bar
8 8 8
Nominal heat rating
kW
10,2
14,2
14,2
Useful rating
kW
8,7
12,1
12,5
Heating time for DHW t 45°C
min.
42
41
49
Heat loss at 60° Celsius
W
270
310
340
Hot water
fl
ow rate
supply at 30K
I/h
249
347
358
supply at 45K
l/h
166
231
239
Erp
Declared Load pro
fi
le
L
L
XL
Water heating e
ffi
ciency
η
wh
%
66,1
66,1
62,9
Water Heating e
ffi
ciency class
B
B
B
Daily electricity consumption Q
elec
kWh
0,040
0,064
0,167
Daily fuel consumption Q
fuel
kWh
19,298
19,214
33,105
Sound power level LWA L
WA
dB
51
51
51
Emissions of nitrogen oxides
[mg/kWh]
129
143
125
Annual electricity consumption AEC
kWh/annum
9
14
37
Annual fuel consumption AFC
GJ/annum
14
14
24
Mixed water at 40°C V40
l
156
182
221
Set-point temperature “out of the box”
°C
60
60
60
Thermostat temperature settings
“E” (Eco)
“E” (Eco)
“E” (Eco)
Gas supply pressure
G20 Methane
mbar
20 20
20
G30 Butane LPG
mbar
28 ÷ 30
28 ÷ 30
28 ÷ 30
G31 Propane LPG
mbar
37 37 37
gas consumption
G20 Methane
m
3
/h
1,079
1,503
1,503
G30 Butane LPG
g/h
803
1118
1118
G31 Propane LPG
g/h
792
1103
1103
Combustion gas values
Draught
mbar
0,015 0,015 0,015
Flue gas
fl
ow rate
g/sec
9,4
10,8
10,2
Flue gas temperature
°C
130
164
143
For the list of equivalent models refer to Annex A, an integral part of this booklet.
The products without the label and its board for sets of heaters and solar devices, provided for in Regulation 812/2013,
are not intended for use in such sets.
TECHNICAL DATA
Содержание 12HP CA-E
Страница 67: ...67 ...