64
GB
• verifying the ventilation features of the
premises and evacuation of the combu-
stion products.
• cleaning the fumes duct.
Prior to this, it is necessary to remove the gas
unit and the fumes de
fl
ector. After such ope-
ration, verify the seal of the gas circuit and the
calibration of the entire unit.
NB: The internal body of the water heater
must not, during such operation, su
ff
er
blows that might damage the internal pro-
tective covering.
4.
Decalci
fi
cation:
this operation is recom-
mended in areas with very hard waters
and when required (less amount of hot
water supplied by the appliance). We
recommend using a 10-20% solution of
hydrogen chloride and phosphoric acid
and, however, using special products for
decalci
fi
cation of galvanised steel boilers;
we also recommend complying with the
use instructions attached to the same pro-
ducts.
Proceed as follows:
• disconnect the appliance from the mains
and drain it using the drain cock (
fi
g. 2);
•
fi
ll the storage with a water and acid solu-
tion, in compliance with the use instructions
of the same;
• leave the solution to act and, possibly with
a pump, recirculate the water through the
hot water outlet pipe and drain cock;
• drain the storage and carry out a prolonged
passivation washing by making the mains
water circulate.
Attention to the water quality!
To assure maximum duration of your applian-
ce, respect certain rules:
LIMESTONE WATER: envision an e
ffi
cient
anti-limescale device, with polyphosphate
crystals base.
SOFT WATER: it must have a TH between 12°
and 15° and a PH above.
SAFETY DEVICE
The appliance is equipped with a device act at
avoiding that the water temperature exceeds
a maximum value set in factory.
Such safety acts so as to create an interrup-
tion to the gas
fl
ow, meaning by completely
switching o
ff
the appliance. The re-ignition
must be carried out as described in paragraph
“IGNITION”, after having eliminated the cau-
ses that determined the switching o
ff
.
AFTER-SALES TECHNICAL ASSISTANCE
In case of fault, irregular functioning or checks
in general, contact the quali
fi
ed authorised
area AFTER-SALES TECHNICAL ASSISTAN-
CE CENTRE for intervention on this appliance.
Any replacements must be carried out only by
quali
fi
ed sta
ff
, using only original spare parts.